Electrical Application Details for App #: B399484
NO PRE-BIS PLACE OF ASSEMBLY CERTIFICATES FOUND
Premises: 371 HUMBOLDT STREET BROOKLYN BIN: 3425791     Block: 2760   Lot: 28
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 771 METROPOLITAN AV Census Tract:   497 Health Area:  0800
HUMBOLDT STREET Admin Area:   B - BROOKLYN Inspection Area:   B
BROOKLYN, NY 11211 Community Board:   301
Special Place Name:   TEMP WIRING
Related Job Number:    320627390
DOB Cross Street(s):   GRAHAM AVENUE,    HUMBOLDT STREET
Status:   C - JOB IS SIGNED OFF 10/18/2017
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  08/11/2015 4:35 PM
Application Entered:   08/11/2015 Job Start Date:   08/11/2015
Last Change:   10/18/2017 Job End Date:   12/30/2016
Appointment Status:   
Last Inspection By:   JOHN, CHARLES       On     10/17/2017      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 011671 Licensee Name: ANGELO ARFANIS
Firm: 003576 Firm Name: FRACCAVENTO ELEC. CORP
Firm Phone: 718-621-9335  Firm Address: 2375 MCDONALD AVE BROOKLYN NY 11223 

Work Started or Filed by Others: NO
Work Category:   N - NEW BUILDING Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
2 - TEMPORARY CONSTRUCTION
T - TEMPORARY LIGHT & POWER
Total Fee:  $240.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   YES
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   Z - Commercial/Residential (3  Stores, 80 Apartments)
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: YOGER TOMER
Owner Business Name: 781 METROPOLITAN AVE LLC
Authorized Representative:  YOGER TOMER
Relationship To Owner:   OWNER


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  1  1-200A
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  ONE SET 3/0 WIRE
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  1   200 AMP PANEL
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
GND                       
Buildings Total                       
Total Units : 1 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 1 #10-Wire 0
Existing Meters 0 + New Meters 1 - Removed Meters 0 = Total Meters 1

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 08/11/2015 Notice:  
Power Issued: 08/11/2015 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  TEMP SERVICE FOR CONNECTION OF CONSTRUCTION HOIST/ELEVATOR NO CONTROL WIRING OF ELEVATOR/HOIST

 
Inspection Details
 

*NO PRE-BIS PLACE OF ASSEMBLY CERTIFICATES FOUND
INSPECTION FOR APPLICATION #: B399484
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 10/17/2017 10/18/2017 CJH C (42) (0) Y
INSPECTION COMMENTS: TEMP WORK REMOVED PRIOR TO INSPECTION