Premises: 244 7 AVENUE MANHATTAN BIN: 1014176     Block: 774   Lot: 7501
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 252 7 AV Census Tract:   91 Health Area:  5200
APT 11I Admin Area:   M - MANHATTAN Inspection Area:   P
NEW YORK, NY 10001 Community Board:   104
Related Job Number:    122694940
DOB Cross Street(s):   WEST 24 STREET,    WEST 25 STREET
Status:   C - JOB IS SIGNED OFF 10/25/2016
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  05/01/2016 11:35 AM
Application Entered:   05/01/2016 Job Start Date:   05/02/2016
Last Change:   10/25/2016 Job End Date:   07/31/2016
Appointment Status:   
Last Inspection By:   CONROY BLAKE       On     10/19/2016      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 011008 Licensee Name: LAURENCE H ROBIN
Firm: 001260 Firm Name: ROBIN ELECTRICAL CO., INC
Firm Phone: 718-292-6535  Firm Address: 437 EAST 165TH ST. B704 BRONX NY 10456 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $95.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: THOMAS LAZZARI
Owner Business Name: CHELSEA MERCANTILE CONDO
Authorized Representative:  RESIDENCE BAILLE
Relationship To Owner:   CONDO OWNER


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  APT PANEL
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
011  11I  70  10    20  70             
Buildings Total 70  10    20  70                
Total Units : 170 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 10/04/2016
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  RENOVATE KITCHEN & BATHROOMS & NEW LIGHTING

 
Inspection Details
 

*NO PRE-BIS PLACE OF ASSEMBLY CERTIFICATES FOUND
INSPECTION FOR APPLICATION #: M381077
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 10/03/2016 10/04/2016 MQY V (37) (2)
INSPECTION COMMENTS: ISSUED OBJECTIONS
 
(2) 10/19/2016 10/21/2016 CBK C R (40) (0)
INSPECTION COMMENTS: OBJECTION REMOVED.

OBJECTION FOR APPLICATION #: M381077
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
(FLOOR: 011) ISLAND RECEPTACLE NEEDS TO BE GFCI PROTECTED (210.8)
RSLV 10/03/2016 10/03/2016 10/19/2016
 
002 (999) OTHER
(FLOOR: 011)RECEPTACLE PLACEMENT IN 1 OUT OF THE 3 BATHROOMS IS NOT AS PER(210.52)
RSLV 10/03/2016 10/03/2016 10/19/2016