NO PRE-BIS PLACE OF ASSEMBLY CERTIFICATES FOUND
Premises: 1116 64 STREET BROOKLYN BIN: 3141996     Block: 5745   Lot: 12
   
Application Completed and Certified

Filed: 1116 64 ST Census Tract:   212 Health Area:  8020
ENTIRE Admin Area:   B - BROOKLYN Inspection Area:   M
BROOKLYN, NY 11219 Community Board:   310
DOB Cross Street(s):    11 AVENUE,    12 AVENUE
Status:   C - JOB IS SIGNED OFF 07/21/2009
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  12/26/2008 8:21 AM
Application Entered:   12/26/2008 Job Start Date:   12/29/2008
Last Change:   07/21/2009 Job End Date:   03/10/2009
Appointment Status:   
Last Inspection By:   DOYLEY, DEXTER       On     07/16/2009      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 011720 Licensee Name: ERIC K AU
Firm: 003306 Firm Name: ERIC & NG ELEC'L, INC.
Firm Phone: 212-673-4118  Firm Address: 155 SUFFOLK STREET NEW YORK NY 10002 

Work Started or Filed by Others: YES
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $193.75
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   B - Two Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: SHUI QING CHEN
Owner Business Name: OWNER
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  3  100AMP
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  5  #2AWG
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  2  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
BAS  BASE  12  12             
001  1F  12             
002  2F  12             
Buildings Total 28  33  15  28                
Total Units : 109 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 3 #4-Wire 0 #10-Wire 0
Existing Meters 2 + New Meters 3 - Removed Meters 2 = Total Meters 3

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 12/26/2008 Notice: C - CALL TO OFFICE 06/15/2009
Power Issued: 12/26/2008 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

*NO PRE-BIS PLACE OF ASSEMBLY CERTIFICATES FOUND
INSPECTION FOR APPLICATION #: B312151
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 04/28/2009 04/29/2009 PGR N (30) (0) Y
INSPECTION COMMENTS: NO SHOW
 
(2) 04/30/2009 05/01/2009 MC2 V E (5) (8) Y
INSPECTION COMMENTS: N
 
(3) 06/08/2009 06/15/2009 RJO H X (25) (0) Y
INSPECTION COMMENTS: N
 
(4) 07/16/2009 07/21/2009 DEX C R E (40) (0) Y
INSPECTION COMMENTS: N

OBJECTION FOR APPLICATION #: B312151
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 1) SERVICE EQUIPMENT ENCLOSURES ARE NOT BONDED TOGETHER
BSMT S.E. BETWEEN TROFF AND METER CONDUIT NOT PROPERLY SET 250.92
RSLV 04/30/2009 06/08/2009 07/16/2009
 
002 ( 5) SERVICE GROUNDING CONDUCTOR HAS NOT BEEN INSTALLED PROPERLY
BSMT AT WATER MAIN STRANDED CONDUCTOR LUG NOT PROVIDED 250.24
RSLV 04/30/2009 06/08/2009 07/16/2009
 
003 (999) OTHER
BSMT PLP PANEL SUPPLING OTHER BRANCH CIRCUIT 210.25
RSLV 04/30/2009 06/08/2009 07/16/2009
 
004 ( 53) GFCI HAS NOT BEEN PROVIDED
BSMT BATHROOM GFIC RECPT NOT PROVIDED 210.8
RSLV 04/30/2009 06/08/2009 07/16/2009
 
005 ( 46) PANEL HAS NOT BEEN PROVIDED WITH A DIRECTORY
ENTIRE PANELS ALL APTS DIRECTORY NOT PROVIDED 408.4
RSLV 04/30/2009 06/08/2009 07/16/2009
 
006 (999) OTHER
BRANCH CIRCUIT REQUIRED FOR GFIC RECPT 210.12
RSLV 04/30/2009 06/08/2009 07/16/2009
 
007 (999) OTHER
APT PANELS C.B NOT AS PER MFG LISTING 110.3
RSLV 04/30/2009 06/08/2009 07/16/2009
 
008 ( 62) ELECTRICAL PERMIT IS NOT CONSPICUOUSLY POSTED AT THE SITE
OUTSIDE PERMIT TO PERFORM ELECTRICAL WORK NOT POSTED 27-3018B
RSLV 04/30/2009 06/08/2009 07/16/2009