BIS Menu  |  Pre-BIS PA CO Query By Bin  |  Plumb. Inspections  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M120633
NO PRE-BIS PLACE OF ASSEMBLY CERTIFICATES FOUND
Premises: 177 PRINCE STREET MANHATTAN BIN: 1008054     Block: 517   Lot: 7502
  Printable (PDF) version of this Permit  

DOB NOW: Inspections


Filed: 177 PRINCE ST Census Tract:   49 Health Area:  6800
3RD FLR Admin Area:   M - MANHATTAN Inspection Area:   U
NEW YORK, NY 10012 Community Board:   102
DOB Cross Street(s):   THOMPSON STREET,    SULLIVAN STREET
Status:   E - ABANDONED 08/22/2025
Request Type:   P - PICK-UP eFiled:   NO
Application Entered:   06/23/1994 Job Start Date:   07/20/1994
Last Change:   08/22/2025 Job End Date:   07/20/1994
Appointment Status:   
Last Inspection By:   WEISBART, F.       On     10/27/1994      
Field Disp:   V - OBJCTN ISSD: JOB INCOMPLT
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 009858 Licensee Name: MARTIN RUBIN
Firm: 000421 Firm Name: DEVORAH ELECTRIC CORP.
Firm Phone: 718-258-0605  Firm Address: 1491 CONEY ISLAND AVE. BROOKLYN NY 11230 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $15.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: GOLDBERG
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 10      10                
Total Units : 21 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag: V - OBJECTION(S) EXIST
Power Requested: Notice:  06/09/1995
Power Issued: Response: R - REINSPECTION 06/21/1995

Follow-Up: F - FILED TO REMOVE OBJECTION 07/27/1994
Contractor's Comments:  

 
Inspection Details
 

*NO PRE-BIS PLACE OF ASSEMBLY CERTIFICATES FOUND
INSPECTION FOR APPLICATION #: M120633
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 06/09/1994 06/23/1994 FWE W (20) (5)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 08/26/1994 09/08/1994 DH1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 10/27/1994 06/09/1995 FWE V R (55) (2)
INSPECTION COMMENTS: 45 FIX NOT SUPPORTED PROPERLY, 46 BREAKERS NOT MARKED
 
(4) 01/24/1997 07/28/1997 FWE Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application