BIS Menu  |  Pre-BIS PA CO Query By Bin  |  Applications  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M302236
NO PRE-BIS PLACE OF ASSEMBLY CERTIFICATES FOUND
Premises: 81 DELANCEY STREET MANHATTAN BIN: 1005471     Block: 414   Lot: 51
   
Application Completed and Certified

Filed: 103 ORCHARD ST Census Tract:   18 Health Area:  7400
CELLAR, 1ST AND 2ND Admin Area:   M - MANHATTAN Inspection Area:   V
NEW YORK, NY 10002 Community Board:   103
Special Place Name:   L.E.S.T. MUSEUM
Related Job Number:    120091024
DOB Cross Street(s):   BROOME STREET,    DELANCEY STREET
Status:   C - JOB IS SIGNED OFF 07/20/2011
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  04/27/2010 9:56 PM
Application Entered:   04/27/2010 Job Start Date:   05/01/2010
Last Change:   07/20/2011 Job End Date:   05/01/2011
Appointment Status:   
Last Inspection By:   CAMPBELL, C       On     07/12/2011      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  

License #: 011029 Licensee Name: SIMON MAGAMAS
Firm: 002367 Firm Name: COPPER-CITY ELECTRIC CORP
Firm Phone: 212-213-0453  Firm Address: 330 E. 38TH ST.-SUITE 5G NEW YORK NY 10016 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
7 - HVAC WIRING
T - TEMPORARY LIGHT & POWER
Total Fee:  $795.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   YES
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   Z - Other
Store / Other:   MUSEUM
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: BARRY ROSEMAN
Owner Business Name: L.E.S.T MUSEUM
Authorized Representative:  BARRY ROSEMAN
Relationship To Owner:   EXECUTIVE VP


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  2  2-400 AMP
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  1  
B. Over #2 to 1/0  2  2 -4# 2'S
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  2  2 -4# 500MCM
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  3  125 AMP 42 CIR.
D. 3 Phase Over 225 AMPS  1   400 AMP 42 CIR.
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
CEL    40  20    10  40         
GND    50  30    20  50         
002    40  20    10  40         
ROF      10         
Buildings Total 131  71    41  131     18           
Total Units : 392 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 12 #4-Wire 0 #10-Wire 1
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 04/27/2010 Notice:  
Power Issued: 04/27/2010 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

*NO PRE-BIS PLACE OF ASSEMBLY CERTIFICATES FOUND
INSPECTION FOR APPLICATION #: M302236
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 07/12/2011 07/20/2011 CLC C E (30) (0) Y
INSPECTION COMMENTS: NONE




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Pre-BIS PA CO Query By Bin  |  Applications  |  Electrical Inspection Work Order  |  Back