Electrical Application Details for App #: Q18832
NO PRE-BIS PLACE OF ASSEMBLY CERTIFICATES FOUND
Premises: 35-52 94 STREET QUEENS BIN: 4036134     Block: 1467   Lot: 30
   
Application Completed and Certified

Filed: 35-52 94 ST Census Tract:   273 Health Area:  1012
BSMNT Admin Area:   A - QUEENS Inspection Area:   D
QUEENS, NY 11372 Community Board:   403
DOB Cross Street(s):    35 AVENUE,    37 AVENUE
Status:   C - JOB IS SIGNED OFF 10/16/1986
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   11/13/1985 Job Start Date:   10/25/1985
Last Change:   10/16/1986 Job End Date:   10/26/1985
Appointment Status:   
Last Inspection By:   DEUTSCHER, L.       On     10/09/1986      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 009858 Licensee Name: MARTIN RUBIN
Firm: 000421 Firm Name: DEVORAH ELECTRIC CORP.
Firm Phone: 718-258-0605  Firm Address: 1491 CONEY ISLAND AVE. BROOKLYN NY 11230 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
9 - OTHER
Total Fee:  $17.00
Other Work:   X
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   C - Three Family
Special Cert Approval:   B - BOILER CONTROLS J-51 CERTIFICATION
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: BERTA WIETZ/37-14 89 QNS
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  1  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                 
Total Units : 4 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Wires Comments: INSTALLING MANUAL RESET PRESSURTROL/1-8FT.FLOURES./WIRED #2 OIL BURN
Contractor's Comments:  X E

 
Inspection Details
 

*NO PRE-BIS PLACE OF ASSEMBLY CERTIFICATES FOUND
INSPECTION FOR APPLICATION #: Q18832
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 12/09/1985 LD1 N (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 05/16/1986 06/11/1986 LD1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 07/01/1986 08/01/1986 LD1 N (20) (0)
INSPECTION COMMENTS: NO ACCESSS SO SUPT ALL DOORS LOCKED SEND LETTER FOR ACCESS
 
(4) 10/09/1986 10/16/1986 LD1 C (40) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application