NO PRE-BIS PLACE OF ASSEMBLY CERTIFICATES FOUND
Premises: 640 50 STREET BROOKLYN BIN: 3013351     Block: 793   Lot: 19
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 640 50 ST Census Tract:   98 Health Area:  6500
CEL THRU 4TH FL Admin Area:   B - BROOKLYN Inspection Area:   J
BROOKLYN, NY 11220 Community Board:   307
Related Job Number:    321537716
DOB Cross Street(s):    6 AVENUE,    7 AVENUE
Status:   C - JOB IS SIGNED OFF 05/29/2019
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  11/29/2017 12:40 PM
Application Entered:   11/29/2017 Job Start Date:   11/29/2017
Last Change:   05/29/2019 Job End Date:   10/01/2019
Appointment Status:   
Last Inspection By:   SERGIY MOTORIN       On     05/29/2019      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 011769 Licensee Name: ZHENG LI
Firm: 003451 Firm Name: KJK ELECTRIC INC
Firm Phone: 917-682-3886  Firm Address: 79 BRIDGEWATER STREET BROOKLYN NY 11222 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
8 - BOILER/BURNER WIRING
Total Fee:  $326.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   YES
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   Z - Commercial/Residential (1  Stores, 6 Apartments)
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: ZHONG YONG CHEN
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  2  COMBO
B. 101 Up to 200 AMPS  1  200 AMPS KNIFE SWITCH
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  7  6 X #6 AWG, 1 X #4 AWG
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  1  350 MCM
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
CEL    15             
001    23             
002    10  30  10  10             
003    10  30  10  10             
004    18             
Buildings Total 40  116  16  38  40                
Total Units : 250 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 8 #4-Wire 0 #10-Wire 0
Existing Meters 5 + New Meters 8 - Removed Meters 5 = Total Meters 8

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 11/29/2017 Notice: 1 - FIRST NOTICE 05/16/2019
Power Issued: 11/29/2017 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  CONVERT TO A MIXED-USED BUILDING, FROM 4-FAMILY TO 6-FAMILY, TO OBTAIN NEW C/O

 
Inspection Details
 

*NO PRE-BIS PLACE OF ASSEMBLY CERTIFICATES FOUND
INSPECTION FOR APPLICATION #: B437800
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 05/11/2019 05/13/2019 OSZ V (40) (11)
INSPECTION COMMENTS: CONTRACTOR MUST AMEND APP FOR F.A.-OBJECTIONS ISSUED.
 
(2) 05/16/2019 05/16/2019 SGY V Y (35) (1)
INSPECTION COMMENTS: STILL OUTSTANDING 4 OBJECTIONS FOR BASEMENT.
 
(3) 05/29/2019 05/29/2019 SGY C R (15) (0)
INSPECTION COMMENTS: OBJECTIONS RESOLVED.

OBJECTION FOR APPLICATION #: B437800
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 18) DEFECTIVE RECEPTACLES ARE IN USE
(FLOOR: 001)DEFECTIVE BATHROOM GFCI (CONDUCTOR WONT LOCK IN PLACE WITH SCREW).ART. 110.2
RSLV 05/11/2019 05/11/2019 05/16/2019
 
002 ( 34) KNOCKOUTS ARE NOT CLOSED IN PANEL BOX
(FLOOR: 003) KO IN PANEL. ART. 110.12(A)
RSLV 05/11/2019 05/11/2019 05/16/2019
 
003 (102) ELECTRICAL MATERIAL USED IS NOT SUITABLE FOR THE PURPOSE INTENDED
(ALL FLOORS)EGC FROM MC CABLE IS BEING USED AS TRAVELER CONDUCTOR FOR ALL S.D'S.ART. 330.108
RSLV 05/11/2019 05/11/2019 05/16/2019
 
004 (132) EQUIPMENT/MATERIAL IS NOT PROPERLY GROUNDED
(ALL FLOORS)ALL MC CABLES TO S.D.'S DO NOT HAVE EGC'S TO BOX. ART. 250.148
RSLV 05/11/2019 05/11/2019 05/16/2019
 
005 (132) EQUIPMENT/MATERIAL IS NOT PROPERLY GROUNDED
(ALL FLOORS)EGC'S FROM MC CABLES HAVE EITHER CUTOUT OR NOT TERMINATED IN PANELST-OUT. ART. 250.148
RSLV 05/11/2019 05/11/2019 05/29/2019
 
006 (231) NO OTHER OUTLET
(ALL FLOORS)KITCHEN GFCI'S ARE SHARED WITH LIGHTING CKT'S T-OUT. ART.210.52(B)(2)
RSLV 05/11/2019 05/11/2019 05/16/2019
 
007 (231) NO OTHER OUTLET
(ALL FLOORS)INDOOR AC CKT'S ARE SHARED WITH LIVING ROOM CKT'S T-OUT. AMEND.210.11(4)
RSLV 05/11/2019 05/11/2019 05/16/2019
 
008 ( 46) PANEL HAS NOT BEEN PROVIDED WITH A DIRECTORY
(ALL FLOORS) ALL DIRECTORY ARE MISSED LABELED. ART. 408.4
RSLV 05/11/2019 05/11/2019 05/16/2019
 
009 ( 59) AFCI PROTECTION HAS NOT BEEN PROVIDED
(ALL FLOORS) ALL S.D.'S ARE AFCI PROTECTED. ART. 210.12(B)
RSLV 05/11/2019 05/11/2019 05/16/2019
 
010 (176) INSTALLATION DOES NOT MEET CODE REQUIREMENTS
(BASEMENT) OCPD'S IN PLP AE=RE NOT FOR USE WITH PANEL. ART. 110.3(B)
RSLV 05/11/2019 05/11/2019 05/29/2019
 
011 (999) OTHER
(BASEMENT) CONTRACTOR MUST FILE FOR F.A.
RSLV 05/11/2019 05/11/2019 05/29/2019
 
012 (999) OTHER
(OPEN SPACE) (ART. 210.70(A2)) ENTER LIGHTING FOR LIFT
RSLV 05/16/2019 05/16/2019 05/29/2019