BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: X15034
NO PRE-BIS PLACE OF ASSEMBLY CERTIFICATES FOUND
Premises: 2702 LATTING STREET BRONX BIN: 2073490     Block: 5348   Lot: 32
   
Application Completed and Certified

Filed: 1372 BALCOM AV Census Tract:   194 Health Area:  3210
BASEMENT Admin Area:   Y - BRONX Inspection Area:   K
BRONX, NY 10461 Community Board:   210
DOB Cross Street(s):       
Status:   C - JOB IS SIGNED OFF 08/28/1986
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   02/13/1986 Job Start Date:   02/10/1986
Last Change:   08/18/1986 Job End Date:   02/17/1986
Appointment Status:   
Last Inspection By:   SERRA, N.       On     07/12/1986      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  

License #: 010490 Licensee Name: ANTHONY CAMMARATA
Firm: 001642 Firm Name: ANTHONY L. CAMMARATA
Firm Phone: 718-409-0743  Firm Address: 1673 UNIONPORT ROAD BRONX NY 10462 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $23.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   O - Office Bldg
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: JOHN ILLARI
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  1  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  1  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 1 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: Notice:  
Power Issued: 04/15/1986 Response:  

Follow-Up: K - (CLOSED) 08/18/1986
Wires Comments: #2 WIRE FEEDER 1 #2 SERV EQUIPMT 100AMP 7 JAW METER 1 SERV SWITCH
Contractor's Comments:  E 500

 
Inspection Details
 

*NO PRE-BIS PLACE OF ASSEMBLY CERTIFICATES FOUND
INSPECTION FOR APPLICATION #: X15034
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 05/02/1986 05/22/1986 EA1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 07/12/1986 08/18/1986 NOS C E (60) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order