BIS Menu  |  Pre-BIS PA CO Query By Bin  |  Property Permits  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M279799
NO PREVIOUSLY ISSUED PERMITS FOUND FOR THIS PROPERTY
Premises: 1 BLEECKER STREET MANHATTAN BIN: 1082610     Block: 529   Lot: 7505
  Printable (PDF) version of this Permit  

DOB NOW: Inspections


Filed: 1 BLEEKER ST Census Tract:   55.02 Health Area:  5700
GROUND Admin Area:   M - MANHATTAN Inspection Area:   S
NEW YORK, NY 10012 Community Board:   102
Special Place Name:   THINK COFFEE
DOB Cross Street(s):   BOWERY,    ELIZABETH STREET
Status:   E - ABANDONED 08/22/2025
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  04/22/2008 12:39 PM
Application Entered:   04/22/2008 Job Start Date:   04/22/2008
Last Change:   08/22/2025 Job End Date:   04/29/2008
Appointment Status:   
Last Inspection By:          On          
Field Disp:   
Energize Recommendation:  
Objection Disposition:  

License #: 011175 Licensee Name: DONALD MCGEACHY
Firm: 000436 Firm Name: DONALD MCGEACHY, INC.
Firm Phone: 212-249-0999  Firm Address: 502A EAST 84 STREET NEW YORK NY 10028 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $70.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   O - Office Bldg
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup:
Owner Business Name: THINK COFFEE
Authorized Representative:  SCHERR JASON
Relationship To Owner:   MANANGER


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  1  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 1 #10-Wire 0
Existing Meters 6 + New Meters 1 - Removed Meters 1 = Total Meters 6

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 04/22/2008 Notice:  
Power Issued: 04/22/2008 Response:  

Follow-Up:
Contractor's Comments:  

 
 

*NO PREVIOUSLY ISSUED PERMITS FOUND FOR THIS PROPERTY
INSPECTION FOR APPLICATION #: M279799
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Pre-BIS PA CO Query By Bin  |  Property Permits  |  Electrical Inspection Work Order  |  Back