BIS Menu  |  Plumb. Inspections  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: A247291
NO PREVIOUSLY ISSUED PERMITS FOUND FOR THIS PROPERTY
Premises: 23-21 31 AVENUE QUEENS BIN: 4534905     Block: 570   Lot: 11
   

Filed: 23-23 31 AV Census Tract:   73 Health Area:  0300
STREET LEVEL Admin Area:   A - QUEENS Inspection Area:   A
QUEENS, NY 11106 Community Board:   401
Related Job Number:    402119505
DOB Cross Street(s):    23 STREET,    CRESCENT STREET
Status:   K - CLOSED/CANCELLED 05/01/2007
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  06/26/2006 12:43 AM
Application Entered:   06/26/2006 Job Start Date:   06/27/2006
Last Change:   05/01/2007 Job End Date:   07/06/2006
Appointment Status:   
Last Inspection By:   THEODORE JUNSCH       On     04/23/2007      
Field Disp:   K - OK TO CANCEL
Energize Recommendation:  
Objection Disposition:  

License #: 010786 Licensee Name: JOE ZAGO
Firm: 003185 Firm Name: COMPSEC ELECTRIC CORP.
Firm Phone: 718-392-2540  Firm Address: 27-01 41 AVE LONG ISLAND CITY NY 11101 

Work Started or Filed by Others: NO
Work Category:   N - NEW BUILDING Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
2 - TEMPORARY CONSTRUCTION
6 - GENERAL WIRING
Total Fee:  $113.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   YES
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup:
Owner Business Name: 210 PLACE REALTY CORPORAT
Authorized Representative:  GEORGE PETRAKOS
Relationship To Owner:   MANAGER


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  1  3PH 100A
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  1  4 # 2 THHN
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  1  3PH 100A
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                       
Total Units : 5 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 1 #10-Wire 0
Existing Meters 0 + New Meters 1 - Removed Meters 0 = Total Meters 1

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 06/26/2006 Notice:  
Power Issued: 06/26/2006 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  I WILL INSTALL A TEMPORARY SERVICE, 3 PHASE 100A OUTDOOR.

 
Inspection Details
 

*NO PREVIOUSLY ISSUED PERMITS FOUND FOR THIS PROPERTY
INSPECTION FOR APPLICATION #: A247291
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 04/23/2007 05/01/2007 TJ1 K (0) (0) Y
INSPECTION COMMENTS: TEMP REMOVED BEFORE INSP




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Plumb. Inspections  |  Electrical Inspection Work Order  |  Back