BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: B105046
NO PREVIOUSLY ISSUED PERMITS FOUND FOR THIS PROPERTY
Premises: 406 FLATBUSH AVENUE EXTENSION BROOKLYN BIN: 3000354     Block: 149   Lot: 17
   
Application Completed and Certified

Filed: 406A FLATBUSH AV EXTENSION Census Tract:   33 Health Area:  1200
J0137 1ST FL & BASE Admin Area:   B - BROOKLYN Inspection Area:   D
BROOKLYN, NY 11201 Community Board:   302
DOB Cross Street(s):   DEKALB AVENUE,    FLATBUSH AVENUE
Status:   C - JOB IS SIGNED OFF 10/05/1994
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   10/15/1992 Job Start Date:   10/12/1992
Last Change:   08/12/1994 Job End Date:   10/12/1992
Appointment Status:   
Last Inspection By:   KAGAN, B.       On     08/05/1994      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  G - NO COMMENT
Objection Disposition:  

License #: 010590 Licensee Name: DEMETRIOS VOUYIOUKLIS
Firm: 000755 Firm Name: JIM ELECTRIC CORP.
Firm Phone: 718-833-2389  Firm Address: 223 52ND STREET BROOKLYN NY 11220 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $11.25
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   K - Store
Store / Other:   REST
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: MC O'BRIEN
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                 
Total Units : 15 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

Access:   10AM 5PM Contact Phone:   718 585 7599

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

*NO PREVIOUSLY ISSUED PERMITS FOUND FOR THIS PROPERTY
INSPECTION FOR APPLICATION #: B105046
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 07/01/1994 07/19/1994 JEP Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 08/05/1994 08/12/1994 BK1 C G (35) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order