Overview for Complaint #:3900734 = RESOLVED
Complaint at:  8519 NEW UTRECHT AVENUE BIN: 3165785    Borough: BROOKLYN    ZIP: 11214
Re:  OEM REPORTS A PARTIAL EXTERIOR WALL COLLAPSE

Category Code: 10      DEBRIS/BUILDING - FALLING OR IN DANGER OF FALLING


Assigned To: EMERGENCY RESPONSE TEAM Priority:  A    

Received:   04/12/2023   15:37   Block:  6344 Lot:  57   Community Board:  311
Owner:   MIRAGLIA FUNERAL CHAPELS INC  

Last Inspection:   05/25/2023 - - BY BADGE # 3252
Disposition:   05/25/2023 - Y2 - VACATE ORDER FULLY RESCINDED
Comments:   OBSERVED PARTIAL DEMOLITION AND TEMPORARY SHORING SUBSTANTIALLY CONFORMING TO JOB FILING # B00865771-I1-ST TO ADDRESS EMERGENCY WORK ORDER. THE WORK OBSERVED IS SUPPORTED BY PE LETTER ATTESTING TO THE STRUCTURAL STABILITY AFTER THE EMERGENCY WORK, CERTIFYING THE BUILDING AS RESAFE TO OCCUPY IN ITS CURRENT CONDITION. NOTE: FUTURE FILINGS TO ADDRESS PERMANENT REPAIR SOLUTIONS AND TEMPORARY EQUIPMENT INCLUDING SWS, FENCE & SHORING TO REMAIN UNTIL PERMANENT REPAIR WORK IS COMPLETE.
Prev DOB Violation #:    VIO23-00970 
Prev ECB Violation #:    39083681Y 

Complaint Disposition History

#      Disposition Disposition Inspection Date
Date Code By
 05/25/2023      Y2  VACATE ORDER FULLY RESCINDED        3252       05/25/2023 
      OBSERVED PARTIAL DEMOLITION AND TEMPORARY SHORING SUBSTANTIALLY CONFORMING TO JOB FILING # B00865771-I1-ST TO ADDRESS EMERGENCY WORK ORDER. THE WORK OBSERVED IS SUPPORTED BY PE LETTER ATTESTING TO THE STRUCTURAL STABILITY AFTER THE EMERGENCY WORK, CERTIFYING THE BUILDING AS RESAFE TO OCCUPY IN ITS CURRENT CONDITION. NOTE: FUTURE FILINGS TO ADDRESS PERMANENT REPAIR SOLUTIONS AND TEMPORARY EQUIPMENT INCLUDING SWS, FENCE & SHORING TO REMAIN UNTIL PERMANENT REPAIR WORK IS COMPLETE.
 04/13/2023      Y1  FULL VACATE ORDER ISSUED        2608       04/13/2023 
      Y1-FULL VACTE AS PER FOLLOW UP INSPECTION PERFORMED BY FEU.
 04/12/2023      A8  ECB VIOLATION SERVED        0517       04/12/2023 
      A8 FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER LARGE SECTION OF PARAPET WALL AT FRONT OF BUILDING LOCATED AT 8519 NEW UTRECHT AVENUE APROX 70X 8FT FELL ONTO SIDEWALK LARGE SECTION OF DECORATIVE STONE LOCATED NEAR FRONT ENTRANCE ALSO SEPERATING