BIS Menu  |  Complaint   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Overview for Complaint #:3976745 = RESOLVED
Complaint at:  51 SOUTH 1 STREET BIN: 3062760    Borough: BROOKLYN    ZIP: 11249
Re:  SAFETY COMPLIANCE

Category Code: 7G      CSE - SWEEP
INSPECTIONS : AREA : LOW RISE

Special District: MIXED USE-8 (GREENPOINT-WILLIAMSBURG, BK)

Assigned To: CONSTRUCTION SAFETY ENFORCMENT Priority:  D    

Received:   09/13/2024   14:10   Block:  2390 Lot:  35   Community Board:  301
Owner:   X X  

Last Inspection:   09/23/2024 - - BY BADGE # 3356
Disposition:   09/23/2024 - L2 - STOP WORK ORDER FULLY RESCINDED
Comments:   Water proofing has been done on Existing rubble wall at Exposure 4 and PE letter has been provided from PE on record for violation conditions. All monitoring reports are up to date and on site. Full rescind.
Prev ECB Violation #:    39532398J 

Complaint Disposition History

#      Disposition Disposition Inspection Date
Date Code By
 09/23/2024      L2  STOP WORK ORDER FULLY RESCINDED        3356       09/23/2024 
      Water proofing has been done on Existing rubble wall at Exposure 4 and PE letter has been provided from PE on record for violation conditions. All monitoring reports are up to date and on site. Full rescind.
 09/18/2024      Y5  STOP WORK REINSPECTION FAILURE        3637       09/18/2024 
      Stop all work 10 ft from exposure #4 between 1st pile and exposure 1. Provide letter or amended drawings with construction sequence of how the protruding wall section will either be removed or remain and have a PE look at the wall's stability to ensure it can withstand proposed construction sequence. Call CSE for reinspection to review letterdrawing prior to resuming work in that area.
 09/16/2024      L1  PARTIAL STOP WORK ORDER        3637       09/13/2024 
      Observed 12 workers working on earthwork excavation and installation of rakers, whalers, and timber lagging. Work not conforming to plans. Area on DOB Approved SOE plan page 101 the CMU wall to remain at exposure 4 was removed. Stop all work 10 ft at exposure #4 from 1st pile to exposure 1 and 4, provide engineering report for adjoining property open cavity.


If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.