Disposition |
Disposition |
Inspection |
Date |
|
Date |
Code |
By |
|
| 10 |
08/10/2022 |
L2 |
STOP WORK ORDER FULLY RESCINDED |
3071 |
08/10/2022 |
| |
|
|
EXCAVATED AREA HAS BEEN BACKFILLED, CONTRACTOR REPAIRED DAMAGED ADJ WALL AT EXP#4 |
|
| 9 |
08/31/2021 |
A3 |
FULL STOP WORK ORDER SERVED |
3123 |
08/31/2021 |
| |
|
|
ATOI, THE EXIS STRUCT EXTNSVELY & TEMP SHRED THROUGHOUT CELLAR; NO DESGN DRWNGS AVAIL. PROVIDE A SAFETY MONITORING PLAN, SPECIFY MONITORING TO BE PERFORMED DURING THE DURATION OF WORK. NO NOTICE OF ADJOINING PROPERTY OWNERS AVAIL. CONDITIONS ON SITE, DOES NOT CONFORM TO SOE DRAWINGS REVIEWED, NO SHEETING, SHORING OR BRACING. NO EVIDENCE OF DOWEL PLACEMENT AT THE FOUNDATION WALL AT EXP # 4, FOUNDATION OBSERVED CRACKED, DISPLACED & LEANING INWARDLY TOWARDS THE EXCAVATED AREA. RESCIND DENIED. |
|
| 8 |
04/09/2021 |
A3 |
FULL STOP WORK ORDER SERVED |
2781 |
04/09/2021 |
| |
|
|
FULL SWO AS PER ENGINEERING TEAM ** CSE AUDIT** |
|
| 7 |
04/09/2021 |
L3 |
STOP WORK ORDER PARTIALLY RESCINDED |
3071 |
04/09/2021 |
| |
|
|
FULL SWO RE-INSTATED JOB UNDER REVIEW *****AUDIT******* |
|
| 6 |
11/05/2020 |
Y5 |
STOP WORK REINSPECTION FAILURE |
3071 |
11/05/2020 |
| |
|
|
REINSPECTION DENIED.WORKERS COMPENSATION AND DISABILITY INSURANCE EXPIRED |
|
| 5 |
10/23/2020 |
L3 |
STOP WORK ORDER PARTIALLY RESCINDED |
3040 |
10/22/2020 |
| |
|
|
OK TO CLEAN SITE. BACKFILL & BERM EXP 2 & 3/INSTALL FENCE & REMOVE OLD FORMWORK. NO OTHER WORK ALLOWED. RELEASED FRM AUD |
|
| 4 |
10/13/2020 |
L3 |
STOP WORK ORDER PARTIALLY RESCINDED |
2656 |
10/13/2020 |
| |
|
|
APPOINTMENT NO KEPT, NO RESPONSE TO CALL OR ANY REPRESENTATIVE AT THE LOCATION AT TIME OF INSPECTION. |
|
| 3 |
09/28/2018 |
L3 |
STOP WORK ORDER PARTIALLY RESCINDED |
2270 |
09/28/2018 |
| |
|
|
PER FEU RECOMMENDATION ON 09/28/18, STOP WORK ORDER IS PARTIALLY RESCINDED TO ALLOW TEMPORARY BRACING OF THE EXTERIOR WALL OF ADJACENT PROPERTY 295 AVENUE O UNDER PERMIT # 321845205 ONLY. |
|
| 2 |
08/16/2018 |
A3 |
FULL STOP WORK ORDER SERVED |
2270 |
08/16/2018 |
| |
|
|
PER FEU, EMERGENCY BACKFILL HAS BEEN COMPLETED. FULL STOP WORK ORDER IN EFFECT. |
|
| 1 |
08/15/2018 |
A3 |
FULL STOP WORK ORDER SERVED |
2746 |
08/14/2018 |
| |
|
|
A3- AT REAR OF PREMISE OBSERVED REAR WALL APPROX. 20' X 15' REMOVE. ALSO OBSERVED EXCAVATION AT REAR YARD REMOVE EARTH APPROX. 8' DEEP ALONG THE ENTIRE PROPERTY LINE OF OF REAR YARD AT EXPOSURES 3 & 4 APPROX. 5' W. |
|