Overview for Complaint #:3553064 = RESOLVED
Complaint at:  2259 EAST 14 STREET BIN: 3200753    Borough: BROOKLYN    ZIP: 11229
Re:  THEY TOOK DOWN MORE THAN 50% OF THE WALLS WHICH IS AGAINST THE ZONING CODE

Category Code: 83      CONSTRUCTION - CONTRARY/BEYOND APPROVED PLANS/PERMITS
CONSTRUCTION IN PROGRESS : CONTRARY TO PLAN


Assigned To: BROOKLYN CONSTRUCTION ENFORCEMENT Priority:  B    
311 Reference Number:  1-1-1232311891    

Received:   04/01/2016      Block:  7375 Lot:  47   Community Board:  315
Owner:   CHALOUH, YIHYA  

Last Inspection:   07/03/2023 - - BY BADGE # 2680
Disposition:   07/05/2023 - L2 - STOP WORK ORDER FULLY RESCINDED
Comments:   APPROVED PLANS 321293603 ON SITE APPROVED PLANS SUPERSEDE APPLICATION 321278988 ON VERTICAL EXTENSION OF THE ONE STORY ONE FAMILY DWELLING, OBSERVED WORK CONFORMS WITH APPROVED PLANS ALL ISSUED PERMITS WERE POSTED.
Prev DOB Violation #:    091916C15MC02  091916C15MC03  091916C15MC04 
Prev ECB Violation #:    35209301Z  35209302K  35209303M 

Complaint Disposition History

#      Disposition Disposition Inspection Date
Date Code By
 07/05/2023      L2  STOP WORK ORDER FULLY RESCINDED        2680       07/03/2023 
      APPROVED PLANS 321293603 ON SITE APPROVED PLANS SUPERSEDE APPLICATION 321278988 ON VERTICAL EXTENSION OF THE ONE STORY ONE FAMILY DWELLING, OBSERVED WORK CONFORMS WITH APPROVED PLANS ALL ISSUED PERMITS WERE POSTED.
 05/31/2023      L3  STOP WORK ORDER PARTIALLY RESCINDED        3123       05/31/2023 
      AT TIME OF INSPECTION NO APPROVED DRAWINGS ON SITE. SWO RESCIND REQUEST # 35209301Z-DENIED.
 10/03/2017      L3  STOP WORK ORDER PARTIALLY RESCINDED        2389       10/03/2017 
      PARTIAL RESCIND TO PERFORM ELECTRICAL WORK UNDER VALID PERMIT B413402 ONLY.
 09/20/2017      L3  STOP WORK ORDER PARTIALLY RESCINDED        2188       09/20/2017 
      REQUEST TO RESCIND SWO ISSUED FOR JOB NOT CONFORMING TO APPROVED PLANS DENIED. THE JOB DONE STILL DOESN'T CONFORM TO AMENDED PLANS.
 12/23/2016      L3  STOP WORK ORDER PARTIALLY RESCINDED        2389       12/23/2016 
      PARTIAL RESCIND TO RESTORE SITE TO PER PLAN ONLY, 321293603. CONTACT DOB FOR APPOINTMENT WHEN UNAUTHORIZED CHANGES HAVE BEEN CORRECTED.
 11/01/2016      A3  FULL STOP WORK ORDER SERVED        2654       11/01/2016 
      AMEND PLANS TO CONFORM WITH CONDITIONS ON SITE. NO UNSAFE CONDITIONS OBSERVED.
 09/20/2016      A3  FULL STOP WORK ORDER SERVED        2680       09/20/2016 
      NO APPROVED PLANS ON SITE , NO HANDRAILS AROUND STAIRWAY OR ON STAIR CASE ON ANY FLOOR , IMPROPER SCAFFOLD AT EXPOSURE 3&4 ,2 BY 4 & 2 BY 6 WOOD CONSTRUCTION ,NO SCAFFOLD PLANKS . EXCESSIVE DEBRIS.