BIS Menu  |  Electrical Inspection Work Order  |  Applications  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Z106565
NO MARQUEE RECORDS FOUND FOR THIS PROPERTY
Premises: 929 ST NICHOLAS AVENUE MANHATTAN BIN: 1062491     Block: 2107   Lot: 72
   
Application Completed and Certified

Filed: 935 SAINT NICHOLAS AV Census Tract:   239 Health Area:  0710
4B Admin Area:   Z - UPPER MANHATTAN Inspection Area:   B
NEW YORK, NY 10032 Community Board:   112
DOB Cross Street(s):   WEST 155 STREET,    WEST 157 STREET
Status:   C - JOB IS SIGNED OFF 03/26/2014
Request Type:   P - PICK-UP eFiled:   YES
Application Entered:   01/28/2014 Job Start Date:   01/28/2014
Last Change:   03/26/2014 Job End Date:   01/30/2014
Appointment Status:   
Last Inspection By:   GARY MCCALLA       On     02/22/2014      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 011592 Licensee Name: MARK OSTROVSKY
Firm: 001987 Firm Name: OM ELECTRIC, INC
Firm Phone: 212-944-7799  Firm Address: 262 WEST 38TH STREET, RM 1202 NEW YORK NY 10018 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $40.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: MARK SCHARFMAN
Owner Business Name: SCHARFMAN ORGANIZATIONS
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
004  4B                     
Buildings Total                       
Total Units : 1 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  11/15/2005
Power Issued: Response: F - FILED TO REMOVE OBJECTION 01/28/2014

Follow-Up: X - FILED APPL,NOW CLOSED 01/28/2014
Contractor's Comments:  

 
Inspection Details
 

*NO MARQUEE RECORDS FOUND FOR THIS PROPERTY
INSPECTION FOR APPLICATION #: Z106565
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 11/05/2005 11/15/2005 LHY W (30) (2)
INSPECTION COMMENTS: NONE
 
(2) 02/22/2014 03/12/2014 GYM C R (60) (0) Y
INSPECTION COMMENTS: SEE APPLICATION NO Z142094

OBJECTION FOR APPLICATION #: Z106565
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 19) DEFECTIVE WIRING IS IN USE
OPEN-EXPOSE WIRES OVER KITCHEN STOVE
RSLV 11/05/2005 11/05/2005 02/22/2014
 
002 ( 30) OUTLET BOXES ARE NOT SECURED
FOYER LIGHT FIXTURERE;Z102643 *FINAL INSPECTION*
RSLV 11/05/2005 11/05/2005 02/22/2014



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.