Electrical Application Details for App #: B353098
NO MARQUEE RECORDS FOUND FOR THIS PROPERTY
Premises: 119 EAST 59 STREET BROOKLYN BIN: 3103201     Block: 4707   Lot: 14
  Printable (PDF) version of this Permit  

DOB NOW: Inspections


Filed: 119 E 59 ST Census Tract:   936 Health Area:  5520
BASEMENT, APARTMENT Admin Area:   B - BROOKLYN Inspection Area:   G
BROOKLYN, NY 11203 Community Board:   317
DOB Cross Street(s):   CHURCH AVENUE,    SNYDER AVENUE
Status:   E - ABANDONED 08/22/2025
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  08/16/2012 2:22 PM
Application Entered:   08/16/2012 Job Start Date:   08/23/2012
Last Change:   08/22/2025 Job End Date:   09/10/2012
               COMPLETION FEE WAS BILLED
Appointment Status:   
Last Inspection By:          On          
Field Disp:   
Energize Recommendation:  
Objection Disposition:  

License #: 011109 Licensee Name: EDLEY SAVAGE
Firm: 002474 Firm Name: JEM ELEC'L CONSTRUCTION
Firm Phone: 718-771-9335  Firm Address: 240 EAST 46TH STREET BROOKLYN NY 11203 

Work Started or Filed by Others: YES
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $215.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   E - Four Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: PIERRE EVERTON
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  5  4 60A AND 1 100A
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  4  #6 THHN
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  5  PANEL/8-16 CB
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 5 #4-Wire 0 #10-Wire 0
Existing Meters 4 + New Meters 5 - Removed Meters 4 = Total Meters 5

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 08/16/2012 Notice:  
Power Issued: 08/16/2012 Response:  

Follow-Up:
Contractor's Comments:  UPGRADE SERVICE FROM 2 WIRE 60AMP 120VOLT TO 100A 120/208V AND REOCATE METER OUTSIDE. INSTALL SUB-PANEL FOR EACH APARMENT, NO INTERNAL WIRERING TO THE APARTMENTS.

 
 

*NO MARQUEE RECORDS FOUND FOR THIS PROPERTY
INSPECTION FOR APPLICATION #: B353098
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Pre-BIS PA CO Query By Bin  |  Electrical Inspection Work Order  |  Back