BIS Menu  |  Pre-BIS PA CO Query By Bin  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Z014572
NO MARQUEE RECORDS FOUND FOR THIS PROPERTY
Premises: 302 COLUMBUS AVENUE MANHATTAN BIN: 1030071     Block: 1146   Lot: 30
   
Application Completed and Certified

Filed: 302 COLUMBUS AV Census Tract:   161 Health Area:  3500
163 BSMT & GRND FL Admin Area:   Z - UPPER MANHATTAN Inspection Area:   E
NEW YORK, NY 10023 Community Board:   107
DOB Cross Street(s):   WEST 74 STREET,    WEST 75 STREET
Status:   C - JOB IS SIGNED OFF 11/13/1990
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   11/05/1987 Job Start Date:   09/14/1987
Last Change:   01/25/1990 Job End Date:   10/28/1987
Appointment Status:   
Last Inspection By:   COLON, WILFREDO JR       On     12/15/1989      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 009035 Licensee Name: S MELLEN
Firm: 001607 Firm Name: PARAGON ELECTRIC INC.
Firm Phone: 212-555-1212  Firm Address: 10-39 44TH DRIVE QUEENS NY 11101 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $141.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   K - Store
Store / Other:   CLOTHING
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: BASIC ELEMENTS
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  3  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  2  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 49  15      76          10      
Total Units : 150 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

Access:   7:30AM - 3:30PM Contact Phone:   786-9600

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag: R - OBJECTION(S) RESOL
Power Requested: Notice: 1 - FIRST NOTICE 07/28/1989
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

*NO MARQUEE RECORDS FOUND FOR THIS PROPERTY
INSPECTION FOR APPLICATION #: Z014572
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 11/27/1987 12/18/1987 SKR Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 01/15/1988 01/21/1988 VG1 J (36) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 04/27/1988 05/06/1988 VG1 H (40) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 06/17/1988 06/23/1988 VG1 H G (15) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(5) 05/26/1989 06/12/1989 VG1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(6) 07/10/1989 07/28/1989 VG1 V G (35) (5)
INSPECTION COMMENTS: NONE
 
(7) 08/04/1989 09/07/1989 WC1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(8) 12/15/1989 01/25/1990 WC1 C R E (90) (0)
INSPECTION COMMENTS: NONE