Electrical Application Details for App #: B389480
NO MARQUEE RECORDS FOUND FOR THIS PROPERTY
Premises: 55 PEARL STREET BROOKLYN BIN: 3000027     Block: 30   Lot: 1
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 55 PEARL ST Census Tract:   21 Health Area:  1000
ENTIRE Admin Area:   B - BROOKLYN Inspection Area:   C
BROOKLYN, NY 11201 Community Board:   302
Related Job Number:    320514582
DOB Cross Street(s):   PLYMOUTH STREET,    WATER STREET
Status:   C - JOB IS SIGNED OFF 10/15/2016 Balance Paid By Owner
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  12/04/2014 3:11 PM
Application Entered:   12/04/2014 Job Start Date:   12/05/2014
Last Change:   10/15/2016 Job End Date:   12/04/2015
Appointment Status:   
Last Inspection By:   WEISBART, F.       On     05/25/2016      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 010548 Licensee Name: ANTHONY REALE
Firm: 003631 Firm Name: AA REALE ELECTRIC INC
Firm Phone: 718-499-8731  Firm Address: 4223 1ST AVENUE BROOKLYN NY 11232 

Work Started or Filed by Others: YES
Work Category:   N - NEW BUILDING Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $240.25
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   YES
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   Z - Commercial/Residential (1  Stores, 1 Apartments)
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: JARED DELLAVALLE
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  1  1 SET 500 MCM
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  2  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
001    10               
001  STORE               
002    10               
003    10               
004             
Buildings Total 21  43    21  21              
Total Units : 111 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 1 #10-Wire 0
Existing Meters 0 + New Meters 1 - Removed Meters 0 = Total Meters 1

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 12/04/2014 Notice: 1 - FIRST NOTICE 03/22/2016
Power Issued: 12/04/2014 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  THIS APPLICATION IS REPLACING B385989 WE TRIED TO AMEND ANDTHEY SAID I HAD TO CANCEL AND REFILE FOR SECOND METER

 
Inspection Details
 

*NO MARQUEE RECORDS FOUND FOR THIS PROPERTY
INSPECTION FOR APPLICATION #: B389480
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 03/22/2016 03/22/2016 HRB V (50) (7)
INSPECTION COMMENTS: FAILED. MUST FILE WITH RIGHT METER COUNT. DID NOT INSPECT HOUSE. WAS INSPECTED AND PASSED BY ANOTHER INSPECTOR REFF # B385989
 
(2) 05/25/2016 05/25/2016 FWE C R (1) (0)
INSPECTION COMMENTS: SEE B385989 NPI

OBJECTION FOR APPLICATION #: B389480
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (138) METAL RACEWAYS AND ENCLOSURES DO NOT HAVE ELECTRICAL CONTINUITY
(GROUND FLOOR) RACEWAY TO WATER MAIN NOT CONTINUOUS
RSLV 03/22/2016 03/22/2016 05/25/2016
 
002 (185) MULTIPLE SOURCE DISCONNECTS NOT GROUPED/IDENTIFIED
(GROUND FLOOR) 12/3 CIRCUITS NOT ID IN BOTH SERVICE SWITCHES
RSLV 03/22/2016 03/22/2016 05/25/2016
 
003 (220) DOUBLE LUGGING IN SERVICE SWITCH
(GROUND FLOOR) IN MAIN SERVICE SWITCH
RSLV 03/22/2016 03/22/2016 05/25/2016
 
004 (228) USING PANEL AS A RACEWAY
(GROUND FLOOR) MAIN SERVICE SWITCH TO SUB PANEL
RSLV 03/22/2016 03/22/2016 05/25/2016
 
005 (247) SIMULTANEOUS OPENING OF POLES
(GROUND FLOOR)12/3 CIRCUITS NOT ON A 2 POLE BREAKER IN BOTH SERVICE SWITCHES
RSLV 03/22/2016 03/22/2016 05/25/2016
 
006 ( 34) KNOCKOUTS ARE NOT CLOSED IN PANEL BOX
(GROUND FLOOR) IN HOUSE SERVICE SWITCHS
RSLV 03/22/2016 03/22/2016 05/25/2016
 
007 ( 46) PANEL HAS NOT BEEN PROVIDED WITH A DIRECTORY
(GROUND FLOOR) BOTH SERVICE SWITCHES
RSLV 03/22/2016 03/22/2016 05/25/2016