BIS Menu  |  Applications  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M147179
NO MARQUEE RECORDS FOUND FOR THIS PROPERTY
Premises: 90 BEDFORD STREET MANHATTAN BIN: 1010006     Block: 588   Lot: 6
   

Filed: 90 BEDFORD ST Census Tract:   73 Health Area:  6400
1A-D 2A B 3B C Admin Area:   M - MANHATTAN Inspection Area:   R
NEW YORK, NY 10014 Community Board:   102
DOB Cross Street(s):   BARROW STREET,    GROVE STREET
Status:   K - CLOSED/CANCELLED 06/30/1999
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   09/26/1996 Job Start Date:   09/14/1996
Last Change:   06/30/1999 Job End Date:   09/30/1996
Appointment Status:   
Last Inspection By:   SEVERIANO JOHN       On     06/15/1999      
Field Disp:   K - OK TO CANCEL
Energize Recommendation:  
Objection Disposition:  

License #: 010445 Licensee Name: GEORGE MOLLER
Firm: 001909 Firm Name: MOLLER & MOLLER ELEC CORP
Firm Phone: 718-767-3594  Firm Address: 121-12 23RD AVENUE COLLEGE PT. NY 11356 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $478.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: RUDD REALTY
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  1  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  1  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  12  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  12  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 12 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 09/26/1996 Notice:  
Power Issued: 09/26/1996 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

*NO MARQUEE RECORDS FOUND FOR THIS PROPERTY
INSPECTION FOR APPLICATION #: M147179
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 09/21/1998 09/23/1998 SVJ N (5) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 11/27/1998 12/04/1998 SVJ N (15) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 03/04/1999 03/08/1999 SVJ N (10) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 06/15/1999 06/30/1999 SVJ K (20) (0)
INSPECTION COMMENTS: DUPLICATE OF APP#M159340 VIOLATION WRITTEN TO CONTRACTOR