BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: A023705
NO MARQUEE RECORDS FOUND FOR THIS PROPERTY
Premises: 15-34 124 STREET QUEENS BIN: 4467628     Block: 4086   Lot: 1
   

Filed: 123-15 18 AV Census Tract:   925 Health Area:  0210
BASEMENT 1 FLO Admin Area:   A - QUEENS Inspection Area:   B
QUEENS, NY 11356 Community Board:   407
DOB Cross Street(s):    123 STREET,    124 STREET
Status:   K - CLOSED/CANCELLED 05/02/1989
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   01/25/1988 Job Start Date:   01/25/1988
Last Change:   05/02/1989 Job End Date:   02/15/1988
Appointment Status:   
Last Inspection By:   ROGERS J.       On     04/05/1989      
Field Disp:   K - OK TO CANCEL
Energize Recommendation:  G - NO COMMENT
Objection Disposition:  R - REMOVED

License #: 009018 Licensee Name: S KURTZ
Firm: 001846 Firm Name: SEYMOUR KUTRZ C/O D'AMORE
Firm Phone: 718-886-8466  Firm Address: 1427 EAST 102ND ST. BROOKLYN NY 11236 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $167.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   C - Three Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: JOHN SOMMA
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  1  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  1  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  6  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  6  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                       
Total Units : 2 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 6 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag: R - OBJECTION(S) RESOL
Power Requested: 01/25/1988 Notice: C - CALL TO OFFICE 05/09/1988
Power Issued: 01/25/1988 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  BASEMENT AND 1 FLOOR

 
Inspection Details
 

*NO MARQUEE RECORDS FOUND FOR THIS PROPERTY
INSPECTION FOR APPLICATION #: A023705
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 02/25/1988 03/10/1988 ROG A G (45) (7)
INSPECTION COMMENTS: (A)UNNECESSARY USE OF FLEX MET CONDUIT FOR SERV ENT 27.3051(B)FLEX MET CONDUIT USED FOR SERV ENT NOT BONDED 27.3030B(C)SCREWS MISS FR
 
(2) 04/26/1988 05/09/1988 ROG H X G (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 10/18/1988 11/16/1988 ROG H R G (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 04/05/1989 05/02/1989 ROG K (25) (0)
INSPECTION COMMENTS: SEE APP FOR MOR EIN A




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.