Premises: 136 EAST 80 STREET MANHATTAN BIN: 1047489     Block: 1508   Lot: 59
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 136 E 80 ST Census Tract:   140 Health Area:  3600
1ST, 3RD & 4TH Admin Area:   M - MANHATTAN Inspection Area:   J
NEW YORK, NY 10075 Community Board:   108
DOB Cross Street(s):   PARK AVENUE,    LEXINGTON AVENUE
Status:   C - JOB IS SIGNED OFF 04/04/2016
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  07/09/2015 12:30 PM
Application Entered:   07/09/2015 Job Start Date:   07/11/2015
Last Change:   04/04/2016 Job End Date:   04/30/2016
Appointment Status:   
Last Inspection By:   PANAYOTEDIS, STEPHEN       On     03/28/2016      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 010438 Licensee Name: SILVIO HONOVIC
Firm: 000244 Firm Name: BLUE RIBBON ELEC'L CONTRS
Firm Phone: 718-625-5000  Firm Address: 500 SMITH STREET BROOKLYN NY 11231 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
7 - HVAC WIRING
Total Fee:  $237.25
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   A - One Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: RESIDENCE O'BRIEN
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  1  100 AMP SINGLE PHASE
B. 101 Up to 200 AMPS  1  200 AMP THREE PHASE
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  1  3 #2 WIRES
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1   4 3/0
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  1  100 SINGLE PHASE
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
001    12  38    14  46             
003    26    12  14             
004    10  20    10  38             
ROF               
Buildings Total 30  85    37  99              
Total Units : 257 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 1 #10-Wire 0
Existing Meters 1 + New Meters 1 - Removed Meters 1 = Total Meters 1

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 07/09/2015 Notice: 1 - FIRST NOTICE 03/04/2016
Power Issued: 07/09/2015 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

*NO JOBS FOUND WITH YOUR CRITERIA
INSPECTION FOR APPLICATION #: M369741
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 03/03/2016 03/04/2016 UMS V (45) (2)
INSPECTION COMMENTS: PATIO WIRING EXISTING
 
(2) 03/28/2016 04/04/2016 STP C R (30) (0)
INSPECTION COMMENTS: PASS. VIOLATIONS REMOVED

OBJECTION FOR APPLICATION #: M369741
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
(FLOOR: 004) 4TH FLOOR RECEPTACLES NOT GROUNDED. NEC 250.146
RSLV 03/03/2016 03/03/2016 03/28/2016
 
002 (999) OTHER
(FLOOR: 004)4TH FLOOR RECEPTACLE OUTLETS SET BACK TO FAR FROM COMBUSTIBLEMATERIAL. NEC 314.20
RSLV 03/03/2016 03/03/2016 03/28/2016