Electrical Application Details for App #: Z100172
NO JOBS FOUND WITH YOUR CRITERIA
Premises: 2518 FREDERICK DOUGLASS BOULEVARD MANHATTAN BIN: 1084051     Block: 1940   Lot: 3
   
Application Completed and Certified

Filed: 2518 FREDERICK DOUGLAS BLVD Census Tract:   228 Health Area:  1000
NONE Admin Area:   Z - UPPER MANHATTAN Inspection Area:   B
NEW YORK, NY 10030 Community Board:   110
DOB Cross Street(s):   WEST 134 STREET,    WEST 135 STREET
Status:   C - JOB IS SIGNED OFF 05/12/2005
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   04/23/2004 Job Start Date:   04/26/2004
Last Change:   05/12/2005 Job End Date:   04/27/2004
Appointment Status:   
Last Inspection By:   ENDRULAT, P.       On     05/07/2005      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 010719 Licensee Name: HOWARD ZAMKOFF
Firm: 001943 Firm Name: STAT ELECTRIC INC.
Firm Phone: 718-261-5673  Firm Address: 118-21 QUEENS BLVD.-SUITE 311 FOREST HILLS NY 11375 

Work Started or Filed by Others: NO
Work Category:   U - UN-TAGGED SIGN Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $105.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   Z - Other
Store / Other:   BANK
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: ALEX RIVERA
Owner Business Name: MUNICIPAL CREDIT UNION
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 1 Tags:

Sign Dimensions : 1 Ft 6 In  BY  10 Ft 0 In  Total Sq. Ft. of Sign: 15
Sign Type : A
Total Circuits: 1 Total Lamps: 4
Watts (Lamps): 0 Number of Trans: 1 VA of Each Trans: 0
Total Watts or VA: 2 A.W. Gauge of Wire: 12 No. of Sockets Per Circuit: 8
Material/Gauge: ALUMINUM AND PLEXIGLASS
Sign Maker : METRO SIGNS
Sign Maker Address: 6 WEST 28 STREET NY, NY 10001
Shop Address:
Shop Phone:
Shop Location Comments:
Sign Text: 24 HOUR ATM MCU 24 HOUR ATM MUNICIPAL CREDIT

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

*NO JOBS FOUND WITH YOUR CRITERIA
INSPECTION FOR APPLICATION #: Z100172
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 05/07/2005 05/12/2005 PEN C (25) (0) Y
INSPECTION COMMENTS: No Inspection Comments For This Application