BIS Menu  |  Electrical Inspection Work Order  |  Electrical Applications  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Z140471
NO JOBS FOUND WITH YOUR CRITERIA
Premises: 420 AMSTERDAM AVENUE MANHATTAN BIN: 1032663     Block: 1228   Lot: 29
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 420 AMSTERDAM AV Census Tract:   167 Health Area:  3400
GROUND FLOOR Admin Area:   Z - UPPER MANHATTAN Inspection Area:   D
NEW YORK, NY 10024 Community Board:   107
Special Place Name:   YORGURTLAND
Related Job Number:    121685015
DOB Cross Street(s):   WEST 80 STREET,    WEST 81 STREET
Status:   C - JOB IS SIGNED OFF 06/20/2025 Balance Paid By Owner
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  07/22/2013 8:36 PM
Application Entered:   07/22/2013 Job Start Date:   07/23/2013
Last Change:   06/20/2025 Job End Date:   02/01/2014
Appointment Status:   
Last Inspection By:   PIERRE FAYOLA       On     06/18/2025      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 011927 Licensee Name: MIKHAIL UMANSKIY
Firm: 003565 Firm Name: CMY ELECTRICAL CORP
Firm Phone: 718-318-3571  Firm Address: 3379 SHORE PKWY BROOKLYN NY 11235 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
L - LIGHTING WORK
Total Fee:  $361.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   Yes
Job Number:  121685015
Building Used As:   K - Store
Store / Other:   FOOD STORE
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup:
Owner Business Name: 420-428 AMSTERDAM, LLC
Authorized Representative:  ZUZU AGRAVI
Relationship To Owner:   MEMBER


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  1  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  2  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  2  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
BAS                   
GND      34  40  16     
Buildings Total 11    39     40     16      
Total Units : 116 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 10 #4-Wire 0 #10-Wire 1
Existing Meters 11 + New Meters 1 - Removed Meters 1 = Total Meters 11

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 07/22/2013 Notice:  
Power Issued: 07/22/2013 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  NEW 400A SS AND 10PT METER FOR NEW FOOD STORE. NEW GENERAL WIRING.

 
Inspection Details
 

*NO JOBS FOUND WITH YOUR CRITERIA
INSPECTION FOR APPLICATION #: Z140471
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 03/28/2025 03/28/2025 SWR J (40) (0) Y
INSPECTION COMMENTS: INSPECTION INCOMPLETE. CONTRACTOR DID NOT HAD NO TOOLS TO OPEN EQUIPMENT. FULL INSPECTION NEEDED AT NEXT INSPECTION WITH TOOLS. ATOI EDDI.
 
(2) 06/18/2025 06/20/2025 FPY C (1) (0) Y
INSPECTION COMMENTS: OK TO CLOSE THIS APP IS BEING SUPERSEDED BY M01228641




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order  |  Electrical Applications  |  Back