Electrical Application Details for App #: B406311
NO JOBS FOUND WITH YOUR CRITERIA
Premises: 442 LORIMER STREET BROOKLYN BIN: 3338218     Block: 2792   Lot: 2
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 442 LORIMER ST Census Tract:   503 Health Area:  0700
APT. 3 Admin Area:   B - BROOKLYN Inspection Area:   A
BROOKLYN, NY 11206 Community Board:   301
DOB Cross Street(s):   TEN EYCK STREET,    MAUJER STREET
Status:   C - JOB IS SIGNED OFF 03/22/2016
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  01/22/2016 11:58 AM
Application Entered:   01/22/2016 Job Start Date:   01/22/2016
Last Change:   03/22/2016 Job End Date:   03/01/2016
Appointment Status:   
Last Inspection By:   DAMISO COOTE       On     02/26/2016      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 010247 Licensee Name: KENNETH TEICH
Firm: 002200 Firm Name: CONTROL SPEC ELECL SYSTEM
Firm Phone: 718-849-2000  Firm Address: 88-56 MYRTLE AVENUE GLENDALE NY 11385 

Removal of ECB Violation(s): 35149286H              
Work Started or Filed by Others: YES
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $60.75
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup:
Owner Business Name: 54 MAUJER STREET LLC
Authorized Representative:  CARLO CAREDDU
Relationship To Owner:   REPRESENTATIVE


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
003  12    12             
Buildings Total 12    12                
Total Units : 33 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  TO REMOVE VIOLATION # 35149286H

 
Inspection Details
 

*NO JOBS FOUND WITH YOUR CRITERIA
INSPECTION FOR APPLICATION #: B406311
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 02/26/2016 03/01/2016 DIT C (60) (0) Y
INSPECTION COMMENTS: JOB PASS