BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: R046237
NO JOBS FOUND WITH YOUR CRITERIA
Premises: 68 HENDRICKS AVENUE STATEN ISLAND BIN: 5000845     Block: 39   Lot: 19
   
Application Completed and Certified

Filed: 68 HENDRICKS AV Census Tract:   11 Health Area:  0400
A68 NONE Admin Area:   R - STATEN ISLAND Inspection Area:   A
STATEN IS, NY 10301 Community Board:   501
DOB Cross Street(s):   WESTERVELT AVENUE,    BISMARK AVENUE
Status:   C - JOB IS SIGNED OFF 02/04/2009
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   05/27/1994 Job Start Date:   05/18/1994
Last Change:   02/04/2009 Job End Date:   05/22/1994
Appointment Status:   
Last Inspection By:   VAZQUEZ, LOUIS       On     02/03/2009      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 010862 Licensee Name: JAMES MAGRIPLES
Firm: 002142 Firm Name: JEMCO ELECT. CONTRS INC
Firm Phone: 718-658-9500  Firm Address: 92-13 180TH STREET JAMAICA NY 11433 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $49.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   B - Two Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: JOE DEVITA
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  1  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  1  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 2 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: K - CANCELLED Objection Flag:
Power Requested: 03/07/1995 Notice: 1 - FIRST NOTICE 03/07/1995
Power Issued: 05/27/1994 Response:  

Follow-Up: K - (CLOSED)
Wires Comments: CHECK 1229
Contractor's Comments:  

 
Inspection Details
 

*NO JOBS FOUND WITH YOUR CRITERIA
INSPECTION FOR APPLICATION #: R046237
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 11/18/1994 12/09/1994 JEP Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 12/30/1994 01/19/1995 JEP Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 01/27/1995 02/21/1995 JEP Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 03/01/1995 03/07/1995 JEP V B (40) (5)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(5) 02/03/2009 02/04/2009 LV1 C R E (25) (0)
INSPECTION COMMENTS: SEE APPLICATION # R050289




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.