BIS Menu  |  Electrical Applications  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: B029075
NO JOBS FOUND WITH YOUR CRITERIA
Premises: 662 PACIFIC STREET BROOKLYN BIN: 3428828     Block: 1128   Lot: 4
  Printable (PDF) version of this Permit  

DOB NOW: Inspections


Filed: 666 PACIFIC ST Census Tract:   161 Health Area:  2600
111 BLDG.2 Admin Area:   B - BROOKLYN Inspection Area:   D
BROOKLYN, NY 11217 Community Board:   308
DOB Cross Street(s):    6 AVENUE,    CARLTON AVENUE
Status:   E - ABANDONED 08/22/2025
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   10/28/1987 Job Start Date:   07/28/1987
Last Change:   08/22/2025 Job End Date:   10/06/1987
Appointment Status:   
Last Inspection By:   CAMPBELL, C       On     08/23/2006      
Field Disp:   H - NO PROGRESS ON JOB
Energize Recommendation:  B - CANCEL POWER AUTH
Objection Disposition:  X - NOT REMOVED

License #: 009881 Licensee Name: H PARKE
Firm: 000938 Firm Name: MARINE ELECTRIC CORP.
Firm Phone: 212-768-8300  Firm Address: 600 FOURTH AVENUE BROOKLYN NY 11215 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $129.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   F - Factory
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: MARINE ELECTRIC RPD INC
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  1  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  1  
D. 3 Phase Over 225 AMPS  1  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 1 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: K - CANCELLED Objection Flag: V - OBJECTION(S) EXIST
Power Requested: 04/18/1989 Notice: C - CALL TO OFFICE 08/28/2006
Power Issued: 10/28/1987 Response:  

Follow-Up:
Contractor's Comments:  

 
Inspection Details
 

*NO JOBS FOUND WITH YOUR CRITERIA
INSPECTION FOR APPLICATION #: B029075
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 11/13/1987 11/30/1987 WMK Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 01/05/1988 01/15/1988 NEI A B (60) (5)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 03/18/1988 04/04/1988 WMK Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 05/13/1988 06/01/1988 FW1 Z (1) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(5) 07/06/1988 07/11/1988 WMK A R B (50) (9)
INSPECTION COMMENTS: *GREENFIELD LOOSE AT CONNECTOR **SERV AREA UNNECCESSARY USE OF GREENFIELD
 
(6) 11/01/1988 11/09/1988 FW1 H X B (50) (0)
INSPECTION COMMENTS: CTO
 
(7) 12/15/1988 12/29/1988 LRN H X B (30) (0)
INSPECTION COMMENTS: CONTRACTOR NO LONGER IN BUSINESS LARRY COHEN 201 471 6800
 
(8) 04/07/1989 04/18/1989 SS1 H X B (45) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(9) 08/23/2006 08/28/2006 CLC H X (15) (0) Y
INSPECTION COMMENTS: NONE




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Applications  |  Electrical Inspection Work Order  |  Back