Electrical Application Details for App #: B317207
NO JOBS FOUND WITH YOUR CRITERIA
Premises: 573 49 STREET BROOKLYN BIN: 3396952     Block: 775   Lot: 56
   
Application Completed and Certified

Filed: 573 49 ST Census Tract:   98 Health Area:  6500
ENTIRE BUILDING Admin Area:   B - BROOKLYN Inspection Area:   J
BROOKLYN, NY 11220 Community Board:   307
Related Job Number:    310155621
DOB Cross Street(s):    5 AVENUE,    6 AVENUE
Status:   C - JOB IS SIGNED OFF 11/09/2010
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  06/10/2009 9:14 AM
Application Entered:   06/10/2009 Job Start Date:   06/10/2009
Last Change:   11/09/2010 Job End Date:   12/30/2009
Appointment Status:   
Last Inspection By:   DOYLEY, DEXTER       On     11/05/2010      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 010606 Licensee Name: MYRON COHEN
Firm: 003435 Firm Name: A.T. ELEC'L CONTR'G, INC
Firm Phone: 718-234-9250  Firm Address: 1561 64TH STREET BROOKLYN NY 11219 

Work Started or Filed by Others: NO
Work Category:   N - NEW BUILDING Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
8 - BOILER/BURNER WIRING
Total Fee:  $483.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   YES
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: KAMMOK CHEUNG
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  1  #500 MCM
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  8  #6/3
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  8  12-24 CIRCUITS
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
BAS    12               
001    16  40  15  15             
002    16  40  15  15             
003    16  40  15  15             
004    16  40  15  15             
Buildings Total 72  172  24  68  68                
Total Units : 404 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 9 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 9 - Removed Meters 0 = Total Meters 9

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 06/10/2009 Notice: 1 - FIRST NOTICE 08/23/2010
Power Issued: 06/10/2009 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

*NO JOBS FOUND WITH YOUR CRITERIA
INSPECTION FOR APPLICATION #: B317207
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 01/22/2010 01/22/2010 RJO V E (45) (8) Y
INSPECTION COMMENTS: ONLY INSPECTED 1ST FLOOR APTS
 
(2) 03/24/2010 03/29/2010 RJO V R E (40) (3) Y
INSPECTION COMMENTS: N
 
(3) 05/21/2010 05/21/2010 RJO A R E (120) (2) Y
INSPECTION COMMENTS: N
 
(4) 08/18/2010 08/23/2010 RJO A R E (20) (1) Y
INSPECTION COMMENTS: N
 
(5) 11/05/2010 11/09/2010 DEX C R E (10) (0) Y
INSPECTION COMMENTS: N

OBJECTION FOR APPLICATION #: B317207
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 19) DEFECTIVE WIRING IS IN USE
SER SW NOT ACCESSIBLE DOOR DOES NOT OPEN
RSLV 01/22/2010 01/22/2010 03/24/2010
 
002 ( 19) DEFECTIVE WIRING IS IN USE
BOX NOT FASTENED TO WALL IN SER AREA
RSLV 01/22/2010 01/22/2010 03/24/2010
 
003 ( 19) DEFECTIVE WIRING IS IN USE
OUTLET NEXT TO S/S OPEN GND
RSLV 01/22/2010 01/22/2010 03/24/2010
 
004 ( 62) ELECTRICAL PERMIT IS NOT CONSPICUOUSLY POSTED AT THE SITE
1ST FL FRONT COUNTER NOT ENOUGH OUTLETS
RSLV 01/22/2010 01/22/2010 03/24/2010
 
005 ( 59) AFCI PROTECTION HAS NOT BEEN PROVIDED
1ST FL FRONT NO ARCH FAULT FOR BEDROOM OUTLETS LIGHT
RSLV 01/22/2010 01/22/2010 03/24/2010
 
006 ( 19) DEFECTIVE WIRING IS IN USE
DEF BREAKER FOR A/C OUT 1ST FL FRONTBEDROOM
RSLV 01/22/2010 01/22/2010 03/24/2010
 
007 ( 45) FIXTURE NOT INSTALLED IN AN APPROVED MANNER
FIX NOT HUNG IN SER ROOM
RSLV 01/22/2010 01/22/2010 03/24/2010
 
008 ( 19) DEFECTIVE WIRING IS IN USE
ALL RANGE HOOD NOT HARD WIRED
RSLV 01/22/2010 01/22/2010 03/24/2010
 
009 ( 19) DEFECTIVE WIRING IS IN USE
STOVE RANGE HOOD COUNTER TOP SAME ERA
RSLV 03/24/2010 03/24/2010 05/21/2010
 
010 ( 59) AFCI PROTECTION HAS NOT BEEN PROVIDED
SMALL BEDROOM NO ARCH FAULT REAR APT
RSLV 03/24/2010 03/24/2010 05/21/2010
 
011 ( 1) SERVICE EQUIPMENT ENCLOSURES ARE NOT BONDED TOGETHER
SER ENT NOT BONDED
RSLV 03/24/2010 03/24/2010 05/21/2010
 
012 ( 19) DEFECTIVE WIRING IS IN USE
3 FL REAR APT NO SMALL APPLIANCES CKT
RSLV 05/21/2010 05/21/2010 08/18/2010
 
013 ( 63) RECEPTACLE OUTLETS NOT IN SUFFICIENT NUMBER
3 4 FL FRONT REAR LOFT NOT ENOUGH OUTLETS
RSLV 05/21/2010 05/21/2010 08/18/2010
 
014 ( 56) ELECTRICAL MATERIAL USED IS NOT SUITABLE FOR THE PURPOSE INTENDED
GFI FRONT OF HOUSE NO COVER
RSLV 08/18/2010 08/18/2010 11/05/2010