BIS Menu  |  Applications  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M112012
NO JOBS FOUND WITH YOUR CRITERIA
Premises: 244 WAVERLY PLACE MANHATTAN BIN: 1010963     Block: 614   Lot: 25
   
Application Completed and Certified

Filed: 244 WAVERLY PL Census Tract:   77 Health Area:  6100
BSMT Admin Area:   M - MANHATTAN Inspection Area:   R
NEW YORK, NY 10014 Community Board:   102
DOB Cross Street(s):   WEST 11 STREET,    BANK STREET
Status:   C - JOB IS SIGNED OFF 12/11/2009
Request Type:   P - PICK-UP eFiled:   NO
Application Entered:   10/18/1993 Job Start Date:   12/05/1993
Last Change:   12/11/2009 Job End Date:   12/05/1993
Appointment Status:   
Last Inspection By:   REDDINGTON, J.       On     11/10/2009      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 011602 Licensee Name: ANTONINO GENOVESE
Firm: 002962 Firm Name: COBRA ELECTRIC CORP.
Firm Phone: 718-445-0045  Firm Address: 28-20 119TH STREET FLUSHING NY 11354 

Historical Licensees and Firms:
License # Licensee Name Firm # Firm Name  
010623 DEVARDO, GEORGE 001810 ANNA ELECTRIC CORP.

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $10.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: KENNTH NAGIN
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

Access:   MAKE APPOINTMENT Contact Phone:   718 204-0864

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  12/27/1993
Power Issued: Response: F - FILED TO REMOVE OBJECTION 01/03/1994

Follow-Up: X - FILED APPL,NOW CLOSED 01/03/1994
Wires Comments: REPLACE FUSE CLOSED ALL KNOCKOUT REPAIR DISCONNECT SW
Contractor's Comments:  

 
Inspection Details
 

*NO JOBS FOUND WITH YOUR CRITERIA
INSPECTION FOR APPLICATION #: M112012
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 09/30/1993 10/18/1993 FWE W (20) (4)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 08/26/1994 09/16/1994 FWE Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(5) 10/05/1994 10/12/1994 FWE N (10) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(6) 11/10/2009 11/18/2009 SR2 C R (30) (0) Y
INSPECTION COMMENTS: NONE




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Applications  |  Electrical Inspection Work Order  |  Back