Electrical Application Details for App #: M353544
NO JOBS FOUND WITH YOUR CRITERIA
Premises: 79 WEST 12 STREET MANHATTAN BIN: 1009609     Block: 576   Lot: 1
   
Application Completed and Certified

Filed: 79 W 12 ST Census Tract:   63 Health Area:  5700
15 B-C Admin Area:   M - MANHATTAN Inspection Area:   S
NEW YORK, NY 10011 Community Board:   102
DOB Cross Street(s):    5 AVENUE,    AVENUE OF THE AMERICAS
Status:   C - JOB IS SIGNED OFF 12/18/2014
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  05/08/2014 7:56 PM
Application Entered:   05/08/2014 Job Start Date:   05/09/2014
Last Change:   12/18/2014 Job End Date:   09/30/2014
Appointment Status:   
Last Inspection By:   SCHUSZTER, NORBET       On     12/11/2014      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 012015 Licensee Name: MIECZYSLAW KARDASZ
Firm: 003926 Firm Name: MK ELECTRIC CONTR'S, INC
Firm Phone: 718-646-0128  Firm Address: 10 BAY 22ND STREET BROOKLYN NY 11214 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $60.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: NOAH GARSON
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
015  15 C  26  18    22  26             
Buildings Total 26  18    22  26                
Total Units : 92 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 12/04/2014
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

*NO JOBS FOUND WITH YOUR CRITERIA
INSPECTION FOR APPLICATION #: M353544
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 11/24/2014 12/04/2014 EID A (50) (4) Y
INSPECTION COMMENTS: NONE
 
(2) 12/11/2014 12/18/2014 NRS C R (30) (0) Y
INSPECTION COMMENTS: 2X 2 POLES A BREAKER INSTALLED

OBJECTION FOR APPLICATION #: M353544
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (132) EQUIPMENT/MATERIAL IS NOT PROPERLY GROUNDED
BK BEDROOM ZIP SCREW USED AS GROUND MEANS IN PANEL AND A/C RECEP BOX..(210.8)
RSLV 11/24/2014 11/24/2014 12/11/2014
 
002 ( 53) GFCI HAS NOT BEEN PROVIDED
KITCHEN INSUFFICIENT RECEP PROVIDED FOR PENNINSULA (210.8)
RSLV 11/24/2014 11/24/2014 12/11/2014
 
003 ( 59) AFCI PROTECTION HAS NOT BEEN PROVIDED
PANEL 1 AFCI PROTECTION NOT PROVIDED FOR AL LIVING ROOM RECEP. (210.12(B))
RSLV 11/24/2014 11/24/2014 12/11/2014
 
004 ( 11) FEEDER CONDUCTORS ARE NOT OF PROPER SIZE
15 BX #6 COND USED FROM SPLICE BOX TO NEW PANEL: PANEL FUSED AT 70AMPS BASEMENT. BOTH PANELS (215.2)A1)
RSLV 11/24/2014 11/24/2014 12/11/2014