BIS Menu  |  Pre-BIS PA CO Query By Bin  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: B316910
NO JOBS FOUND WITH YOUR CRITERIA
Premises: 6623 FT HAMILTON PARKWAY BROOKLYN BIN: 3142359     Block: 5757   Lot: 35
   
Application Completed and Certified

Filed: 6623 FT. HAMILTON PARKWAY Census Tract:   210 Health Area:  8020
STREET Admin Area:   B - BROOKLYN Inspection Area:   M
BROOKLYN, NY 11219 Community Board:   310
DOB Cross Street(s):    66 STREET,    67 STREET
Status:   C - JOB IS SIGNED OFF 12/11/2009
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  06/01/2009 1:10 PM
Application Entered:   06/01/2009 Job Start Date:   06/02/2009
Last Change:   12/11/2009 Job End Date:   06/02/2010
Appointment Status:   
Last Inspection By:   O'HARE, R.J.       On     12/10/2009      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 011793 Licensee Name: JEONG YUNG
Firm: 003404 Firm Name: INTELOGIC ELECTRIC, INC.
Firm Phone: 718-768-3188  Firm Address: 254 40TH STREET BROOKLYN NY 11232 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $131.25
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   K - Store
Store / Other:   COFFE SHOP
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: ERICA LIU
Owner Business Name: MAPLE BAKERY INC
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  1  200AMP 3 PH 208 V
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  1  200 AMP 3 PH
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
GND  STORE  15  18  15             
Buildings Total 15  18  15                
Total Units : 55 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 1 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 06/01/2009 Notice: 1 - FIRST NOTICE 08/10/2009
Power Issued: 06/01/2009 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

*NO JOBS FOUND WITH YOUR CRITERIA
INSPECTION FOR APPLICATION #: B316910
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 08/07/2009 08/10/2009 JMZ A E (30) (5) Y
INSPECTION COMMENTS: OUTSIDE LIGHTS NO GOOD, SUPPORT RACEWAY, BX NOT GROUNDED, OPEN WIRES, CAFE BLUE GINGER 6619 FT HAMILTON PKWAY
 
(2) 09/14/2009 09/18/2009 RJO H Y (35) (0) Y
INSPECTION COMMENTS: 56 22 STILL REMAINS
 
(3) 11/04/2009 11/06/2009 FMO N (30) (0) Y
INSPECTION COMMENTS: WORKERS IN BATTERY DONT UNDERSTAND INSPECTOR OWNER NO SHOW
 
(4) 12/10/2009 12/11/2009 RJO C R E (50) (0) Y
INSPECTION COMMENTS: N

OBJECTION FOR APPLICATION #: B316910
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 56) ELECTRICAL MATERIAL USED IS NOT SUITABLE FOR THE PURPOSE INTENDED
BASEMENT PANEL GROUNDS DOUBLE LUGGED
RSLV 08/07/2009 08/07/2009 09/14/2009
 
002 ( 22) FIXED EQUIPMENT IS NOT PROPERLY GROUNDED
KITCHEN GROUNDS NOT TERMINATED PROPERLY
RSLV 08/07/2009 09/14/2009 12/10/2009
 
003 ( 45) FIXTURE NOT INSTALLED IN AN APPROVED MANNER
KITCHEN LIGHTS NOT SUPPORTED PROPERLY
RSLV 08/07/2009 09/14/2009 12/10/2009
 
004 ( 22) FIXED EQUIPMENT IS NOT PROPERLY GROUNDED
GROUND RECEPTACLES
RSLV 08/07/2009 09/14/2009 12/10/2009
 
005 ( 29) OUTLET BOXES ARE NOT COVERED
OPEN BOX IN KITCHEN CEILING
RSLV 08/07/2009 09/14/2009 12/10/2009



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.