BIS Menu  |  After Hours Variance Permits  |  Plumb. Inspections  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Z149573
NO JOBS FOUND WITH YOUR CRITERIA
Premises: 331 CENTRAL PARK WEST MANHATTAN BIN: 1031645     Block: 1207   Lot: 29
   
Application Completed and Certified

Filed: 333 CENTRAL PARK W Census Tract:   177 Health Area:  3220
APT 1-A Admin Area:   Z - UPPER MANHATTAN Inspection Area:   D
NEW YORK, NY 10025 Community Board:   107
DOB Cross Street(s):   WEST 93 STREET,    WEST 94 STREET
Status:   C - JOB IS SIGNED OFF 09/16/2015
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  05/12/2015 5:51 PM
Application Entered:   05/12/2015 Job Start Date:   05/12/2015
Last Change:   09/16/2015 Job End Date:   05/11/2016
Appointment Status:   
Last Inspection By:   ELLIS DAVID       On     09/10/2015      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  G - NO COMMENT
Objection Disposition:  R - REMOVED

License #: 011535 Licensee Name: JEFFREY M LIU
Firm: 004269 Firm Name: UNITED ELEC & LIGHTING CO
Firm Phone: 718-740-2200  Firm Address: 200-24 HOLLIS AVENUE CORP SAINT ALBANS NY 11412 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $77.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: ROBERT OLIN
Authorized Representative:  JOHN MCDONALD
Relationship To Owner:   GENERAL CONTRACTOR


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  1  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 1 #4-Wire 0 #10-Wire 0
Existing Meters 1 + New Meters 1 - Removed Meters 0 = Total Meters 2

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 05/12/2015 Notice: 1 - FIRST NOTICE 09/02/2015
Power Issued: 05/12/2015 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

*NO JOBS FOUND WITH YOUR CRITERIA
INSPECTION FOR APPLICATION #: Z149573
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 08/27/2015 09/02/2015 NRS V G (40) (2) Y
INSPECTION COMMENTS: OLD PANEL(NOW SPLICE BOX)STILL PARTIALLY USED AS PANEL
 
(2) 09/10/2015 09/16/2015 EID C R G (20) (0) Y
INSPECTION COMMENTS: NONE

OBJECTION FOR APPLICATION #: Z149573
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (128) NEUTRAL IS GROUNDED BEYOND LOAD SIDE OF SERVICE SWITCH
BASE: METER ENCLOSURE & 200A MAIN SWITCH
RSLV 08/27/2015 08/27/2015 09/10/2015
 
002 (999) OTHER
GR: NO SIMULTANEOUS TRIP FOR CIRCUITS #2,4,6,8(IN OLD PANEL CIRC #2,4,6,8 HAS COMMON NEUTRAL).. 210.4
RSLV 08/27/2015 08/27/2015 09/10/2015



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  After Hours Variance Permits  |  Plumb. Inspections  |  Electrical Inspection Work Order  |  Back