Electrical Application Details for App #: A331739
NO JOBS FOUND WITH YOUR CRITERIA
Premises: 10-38 JACKSON AVENUE QUEENS BIN: 4436600     Block: 40   Lot: 16
   
Application Completed and Certified

Filed: 1040 JACKSON AV Census Tract:   7 Health Area:  0720
CELLAR / FIRST FLOOR Admin Area:   A - QUEENS Inspection Area:   C
QUEENS, NY 11101 Community Board:   402
Special Place Name:   NY IRISH CULTURAL CENTER
Related Job Number:    420115146
DOB Cross Street(s):    51 AVENUE,    50 AVENUE
Status:   C - JOB IS SIGNED OFF 05/26/2015
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  10/27/2014 3:59 PM
Application Entered:   10/27/2014 Job Start Date:   10/27/2014
Last Change:   05/26/2015 Job End Date:   11/30/2014
Appointment Status:   
Last Inspection By:   SOLAVNTO, THOMAS       On     05/19/2015      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 011176 Licensee Name: JAMES J ZERVAS
Firm: 004379 Firm Name: D&D ELECTL CONST CO INC
Firm Phone: 212-524-9411  Firm Address: 18 WEST 27TH STREET, 12TH FLOOR NEW YORK NY 10001 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
L - LIGHTING WORK
Total Fee:  $116.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   YES
This Job Regulated by the NYC Energy Conservation Code:   Yes
Job Number:  420115146
Building Used As:   O - Office Bldg
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: COLM CAMPBELL
Owner Business Name: FAILTE CARE CORP
Authorized Representative:  JOHN BOHAN
Relationship To Owner:   REGISTERED AGENT


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  1  100 AMP
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  1  4X #2 + #6 GROUND
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  1  100
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
CEL                   
001                 
Buildings Total                 
Total Units : 24 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 1 #10-Wire 0
Existing Meters 0 + New Meters 1 - Removed Meters 0 = Total Meters 1

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 10/27/2014 Notice: 1 - FIRST NOTICE 03/17/2015
Power Issued: 10/27/2014 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

*NO JOBS FOUND WITH YOUR CRITERIA
INSPECTION FOR APPLICATION #: A331739
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 12/16/2014 12/22/2014 TS1 P (30) (0) Y
INSPECTION COMMENTS: CONTRACTOR DID NOT KNOW WHAT WAS DONE
 
(2) 03/11/2015 03/17/2015 TSO A E (30) (5) Y
INSPECTION COMMENTS: OBJECTIONS
 
(3) 05/19/2015 05/26/2015 TSO C R E (20) (0) Y
INSPECTION COMMENTS: CERTIFICATE

OBJECTION FOR APPLICATION #: A331739
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
CELLAR MULTIWIRE CIRCUIT NEED GROUP TIES 210.4
RSLV 03/11/2015 03/11/2015 05/19/2015
 
002 ( 33) KNOCKOUTS ARE NOT CLOSED IN OUTLET BOX
CELLAR KNOCKOUTS PANEL
RSLV 03/11/2015 03/11/2015 05/19/2015
 
003 (999) OTHER
CELLAR NEUTRAL GROUNDED LOAD OF SERVICE 250.24
RSLV 03/11/2015 03/11/2015 05/19/2015
 
004 ( 46) PANEL HAS NOT BEEN PROVIDED WITH A DIRECTORY
CELLAR NO PANEL SCHEDULE
RSLV 03/11/2015 03/11/2015 05/19/2015
 
005 (999) OTHER
CELLAR & 1ST FLOOR 2X2 FIXTURES NOT SUPPORTED 410.36
RSLV 03/11/2015 03/11/2015 05/19/2015