BIS Menu  |  Electrical Inspection Work Order  |  Applications  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Z128555
NO JOBS FOUND WITH YOUR CRITERIA
Premises: 6 WEST 139 STREET MANHATTAN BIN: 1087516     Block: 1736   Lot: 7501
   
Application Completed and Certified

Filed: 34 W 139 ST Census Tract:   2120 Health Area:  1300
1ST FLOOR Admin Area:   Z - UPPER MANHATTAN Inspection Area:   B
NEW YORK, NY 10037 Community Board:   110
DOB Cross Street(s):    5 AVENUE,    LENOX AVENUE
Status:   C - JOB IS SIGNED OFF 02/28/2011
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  12/06/2010 9:24 AM
Application Entered:   12/06/2010 Job Start Date:   12/06/2010
Last Change:   02/28/2011 Job End Date:   01/31/2011
Appointment Status:   
Last Inspection By:   DALTON HENLON       On     02/26/2011      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 010659 Licensee Name: PETER J GIOELLO
Firm: 000117 Firm Name: AMBER LITE ELECTRIC CORP.
Firm Phone: 718-605-5200  Firm Address: 441 WILD AVE 2ND FLOOR STATEN ISLAND NY 10314 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $124.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   Z - Other
Store / Other:   COMMUNITY CENTER
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: KEN SAPERSTEIN
Owner Business Name: BEACON MEWS LLC
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
001    110  85    12  110  24     
Buildings Total 110  85    12  110     24         
Total Units : 346 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

*NO JOBS FOUND WITH YOUR CRITERIA
INSPECTION FOR APPLICATION #: Z128555
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 02/01/2011 02/09/2011 CCH Z (0) (0) Y
INSPECTION COMMENTS: NONE
 
(2) 02/26/2011 02/28/2011 DAH C (30) (0) Y
INSPECTION COMMENTS: NONE




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order  |  Applications  |  Back