BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: B352611
NO JOBS FOUND WITH YOUR CRITERIA
Premises: 1257 EAST 18 STREET BROOKLYN BIN: 3180714     Block: 6738   Lot: 74
   
Application Completed and Certified

Filed: 1257 E 18 ST Census Tract:   538
WHOLE HOUSE Admin Area:   B - BROOKLYN Inspection Area:   K
BROOKLYN, NY 11230 Community Board:   314
DOB Cross Street(s):   AVENUE L,    BAY AVENUE
Status:   C - JOB IS SIGNED OFF 05/13/2013
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  08/01/2012 2:53 PM
Application Entered:   08/01/2012 Job Start Date:   08/01/2012
Last Change:   05/13/2013 Job End Date:   08/01/2012
Appointment Status:   
Last Inspection By:   DOYLEY, DEXTER       On     05/10/2013      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 012418 Licensee Name: ELVIS FERNANDEZ
Firm: 004209 Firm Name: FERCO ELECTRIC SERVICE CO
Firm Phone: 718-651-7490  Firm Address: 53-14 ROOSEVELT AVE WOODSIDE NY 11377 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $344.25
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: RACHEL TSATSKIS
Owner Business Name: TSATSKIS
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  1  1 SWITCH FOR EACH METER
B. 101 Up to 200 AMPS  1  MAIN DISCONNECT 200 AMPS
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  7  7 SETS OF # 6 WIRE
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  5  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
GND  20               
001  18               
001  22               
002  18               
002  22               
Buildings Total 31  100  12  32                  
Total Units : 175 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 6 #4-Wire 0 #10-Wire 0
Existing Meters 5 + New Meters 6 - Removed Meters 5 = Total Meters 6

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 08/01/2012 Notice: 1 - FIRST NOTICE 04/30/2013
Power Issued: 08/01/2012 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  RESUBMITTAL OF APPLICATION B352136, UNFORTUNATELY WHEN SUBMITTED SEVERAL MISTAKES WERE POINTED OUT. AND I WAS ADVISED TO REFILE WITH THE CORRECTIONS. THE AMENDMENT REQUEST I WASTOLD IS NOT CURRENTLY WORKING. I WILL BE INSTALLING 6 METERS 1 FOR EACH APT. 1 FOR PLP.

 
Inspection Details
 

*NO JOBS FOUND WITH YOUR CRITERIA
INSPECTION FOR APPLICATION #: B352611
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 04/22/2013 04/30/2013 JSB A E (60) (5) Y
INSPECTION COMMENTS: N
 
(2) 05/10/2013 05/13/2013 DEX C R E (30) (0) Y
INSPECTION COMMENTS: N

OBJECTION FOR APPLICATION #: B352611
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
PLP SVC SW COMBO NOT SUITABLE FOR USE 110.3
RSLV 04/22/2013 04/22/2013 05/10/2013
 
002 (999) OTHER
ALL APT FEEDERS REIDENTIFIED #6 USED 200.6
RSLV 04/22/2013 04/22/2013 05/10/2013
 
003 (999) OTHER
BSMT UTILITY GRD BAR NOT INSTALLED 250.94
RSLV 04/22/2013 04/22/2013 05/10/2013
 
004 (999) OTHER
KITCHEN COUNTER OUTLET DEVICES MISSING 210.8
RSLV 04/22/2013 04/22/2013 05/10/2013
 
005 ( 25) ARMORED CABLES ARE NOT PROPERLY TERMINATED
BOX TAILS FOR DISH WASHER
RSLV 04/22/2013 04/22/2013 05/10/2013



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order