Electrical Application Details for App #: B012141
NO JOBS FOUND WITH YOUR CRITERIA
Premises: 192 SACKETT STREET BROOKLYN BIN: 3250518     Block: 337   Lot: 11
   
Application Completed and Certified

Filed: 192 SACKETT ST Census Tract:   63 Health Area:  4000
ENTIRE BLDG RE:VI#24745-86 Admin Area:   B - BROOKLYN Inspection Area:   C
BROOKLYN, NY 11231 Community Board:   306
DOB Cross Street(s):   HICKS STREET,    HENRY STREET
Status:   C - JOB IS SIGNED OFF 11/03/1988
Request Type:   P - PICK-UP eFiled:   NO
Application Entered:   11/25/1986 Job Start Date:   12/12/1986
Last Change:   11/01/1988 Job End Date:   04/01/1987
Appointment Status:   
Last Inspection By:   ROSE, M.       On     10/25/1988      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 010539 Licensee Name: MARTIN LOETTERLE
Firm: 001721 Firm Name: FRITZMARTIN ELECTRIC INC.
Firm Phone: 718-624-2255  Firm Address: 76 DEGRAW STREET BROOKLYN NY 11231 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $299.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   C - Three Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: STEVE LEGUSTA
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  1  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  
D. Over 250 MCM  0  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  8  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  9  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 50  130  14  46  50                
Total Units : 290 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

Access:   DAILY Contact Phone:   624-2255

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 9 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag: R - OBJECTION(S) RESOL
Power Requested: 01/15/1987 Notice:  11/25/1986
Power Issued: 01/15/1987 Response: F - FILED TO REMOVE OBJECTION 01/15/1987

Follow-Up: X - FILED APPL,NOW CLOSED 01/15/1987
Wires Comments: REMOVE VIO THROUGH TOTAL REWIRING EIGHT FAMILY DWELLING
Contractor's Comments:  

 
Inspection Details
 

*NO JOBS FOUND WITH YOUR CRITERIA
INSPECTION FOR APPLICATION #: B012141
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 11/27/1985 11/25/1986 LDM W (1) (5)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 10/25/1988 11/01/1988 MX1 C R E (75) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application