Electrical Application Details for App #: B096378
NO JOBS FOUND WITH YOUR CRITERIA
Premises: 1672 OCEAN AVENUE BROOKLYN BIN: 3180535     Block: 6730   Lot: 1
   
Application Completed and Certified

Filed: 1680 OCEAN AV Census Tract:   760 Health Area:  7310
APT 5B Admin Area:   B - BROOKLYN Inspection Area:   K
BROOKLYN, NY 11230 Community Board:   314
DOB Cross Street(s):   EAST 19 STREET,    OCEAN AVENUE
Status:   C - JOB IS SIGNED OFF 12/11/1997
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   03/11/1992 Job Start Date:   02/25/1992
Last Change:   11/18/1997 Job End Date:   02/26/1992
Appointment Status:   
Last Inspection By:   ROBERT SPRUNG       On     11/13/1997      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  G - NO COMMENT
Objection Disposition:  

License #: 010717 Licensee Name: R KALANZ
Firm: 001942 Firm Name: R K ELECT'L CONTRS INC.
Firm Phone: 718-726-7248  Firm Address: 20-47 STEINWAY STREET QUEENS NY 11105 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $25.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   C - Three Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: PHYLIS CAGAN
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                       
Total Units : 2 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  718 258 4524

 
Inspection Details
 

*NO JOBS FOUND WITH YOUR CRITERIA
INSPECTION FOR APPLICATION #: B096378
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 04/22/1992 04/27/1992 LF1 N (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 10/06/1997 10/09/1997 RSP P (60) (0) Y
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 11/13/1997 11/18/1997 RSP C G (60) (0) Y
INSPECTION COMMENTS: No Inspection Comments For This Application