| NYC Department of Buildings | ||
| Electrical Application Details for App #: M324175 | ||
| NO JOBS FOUND WITH YOUR CRITERIA | ||
| Premises: 156 PRINCE STREET MANHATTAN | BIN: 1007732 Block: 502 Lot: 20 |
| Application Completed and Certified | ||
| Filed: | 156 PRINCE ST | Census Tract: 49 | Health Area: 6800 | |
| APT 6B,1A,3A | Admin Area: M - MANHATTAN | Inspection Area: U | ||
| NEW YORK, NY 10012 | Community Board: 102 | |||
| DOB Cross Street(s): WEST BROADWAY, THOMPSON STREET | |||
| Status: C - JOB IS SIGNED OFF 08/28/2014 | |||
| Request Type: A - APPLICATION | eFiled: YES | Permit Issued: 02/28/2012 12:56 PM | |
| Application Entered: 02/28/2012 | Job Start Date: 02/28/2012 | ||
| Last Change: 08/28/2014 | Job End Date: 04/25/2012 | ||
| Appointment Status: | |||
| Last Inspection By: AGELONIAS, ANASTASIOS On 05/27/2014 | |||
| Field Disp: C - INSPECTION PASSED | |||
| Energize Recommendation: | |||
| Objection Disposition: R - REMOVED | |||
| License #: | 011252 | Licensee Name: | ALBERT V DATTOLO | |
| Firm: | 001211 | Firm Name: | RAINBOW ELECTRIC CO., INC | |
| Firm Phone: | 718-521-0926 | Firm Address: | 76-18 ROCKAWAY BLVD WOODHAVEN NY 11421 | |
| Work Started or Filed by Others: YES | ||||||||
| Work Category: R - REHABILITATION | Work To Be Done:
6 - GENERAL WIRING |
Total Fee: $126.25 | ||||||
| Other Work: | ||||||||
| Work Related to a New or Amended Certificate of Occupancy: NO | ||||||||
| This Job Regulated by the NYC Energy Conservation Code: No | ||||||||
| Building Used As: L - Five Or More Family | |||||||
| Special Cert Approval: | |||||||
| Advisory Board Approval: NOT APPLICABLE | |||||||
| Owner / Occup: | PEDRO CASTILLO | ||||||
| Owner Business Name: | PEDRO CASTILLO ARCH | ||||||
| Authorized Representative: | |||||||
| Relationship To Owner: | |||||||
|
|
| Floor | Apt. | Number Of Outlets | No. Of Fixtures |
Motors / Generators | Heaters | Transformers | ||||||
| Fixt | Receptacles | Switch | Num | Total HP KW | Num | Total KW | Num | Total KVA | ||||
| ATT | A/C | |||||||||||
| 001 | 1A | 12 | 30 | 3 | 12 | 12 | ||||||
| 003 | 3A | 10 | 20 | 3 | 12 | 12 | ||||||
| 006 | 6B | 10 | 15 | 1 | 5 | 18 | ||||||
| Buildings Total | 32 | 65 | 7 | 29 | 42 | |||||||
| Total Units : 175 units | ||||||||||||
| Signs: | Field Connect: | 0 | Field Inspect: | 0 | Tags: | ||
| Meter Request to Utility | #3-Wire | 0 | #4-Wire | 0 | #10-Wire | 0 | |
| Existing Meters | 0 | + New Meters | 0 | - Removed Meters | 0 | = Total Meters | 0 |
| Power Auth Flag: | Objection Flag: | ||
| Power Requested: | Notice: | 1 - FIRST NOTICE 05/18/2012 | |
| Power Issued: | Response: |
| Follow-Up: | K - (CLOSED) | ||
| Contractor's Comments: GUT REHAB WITH PANEL CHANGE FOR EACH APT. RISER IS EXISTING. | |||
|
|
| *NO JOBS FOUND WITH YOUR CRITERIA |