NYC Department of Buildings
Electrical Application Details for App #: B307821
NO JOBS FOUND WITH YOUR CRITERIA
Premises: 2979 OCEAN AVENUE BROOKLYN BIN: 3204405     Block: 7441   Lot: 238
   
Application Completed and Certified

Filed: 2979 OCEAN AV Census Tract:   594.01 Health Area:  8722
BSMT , 1ST ,2ND ,3RD FL. Admin Area:   B - BROOKLYN Inspection Area:   P
BROOKLYN, NY 11235 Community Board:   315
DOB Cross Street(s):   AVENUE Y,    AVENUE Z
Status:   C - JOB IS SIGNED OFF 10/13/2009
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  08/14/2008 4:51 PM
Application Entered:   08/14/2008 Job Start Date:   08/15/2008
Last Change:   10/13/2009 Job End Date:   12/25/2009
Appointment Status:   
Last Inspection By:   COHN, MARTIN       On     10/08/2009      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 011267 Licensee Name: ALEXANDER ABRAMOVICH
Firm: 002666 Firm Name: INTEGRAL ELECL PWR & CNTR
Firm Phone: 212-645-5528  Firm Address: 307 7TH AVENUE,SUITE 301 NEW YORK NY 10001 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $365.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   Z - Commercial/Residential (1  Stores, 2 Apartments)
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: IGOR KISIN
Owner Business Name: PRIME CORNER LLC
Authorized Representative:  IGOR KISIN
Relationship To Owner:   OWNER


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  2  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  2  
B. Over #2 to 1/0  2  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  2  
C. 3 Phase Up to 225 AMPS  1  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 18  74    22  32              
Total Units : 150 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 3 #4-Wire 1 #10-Wire 0
Existing Meters 3 + New Meters 1 - Removed Meters 0 = Total Meters 4

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 08/14/2008 Notice: 1 - FIRST NOTICE 09/08/2009
Power Issued: 08/14/2008 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  RENOVATION TWO APARTMENT END 1ST FLOOR FUTURE COMERCIAL SPACE.

 
Inspection Details
 

*NO JOBS FOUND WITH YOUR CRITERIA
INSPECTION FOR APPLICATION #: B307821
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 09/01/2009 09/08/2009 MC2 V E (40) (8) Y
INSPECTION COMMENTS: N
 
(2) 10/08/2009 10/13/2009 MC2 C R E (30) (0) Y
INSPECTION COMMENTS: N

OBJECTION FOR APPLICATION #: B307821
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
BSMT 2ND 3RD FL PLP PANELS BONDED AFTER SERVICE SWITCH 250.24
RSLV 09/01/2009 09/01/2009 10/08/2009
 
002 ( 7) EMT IS NOT PROPERLY SUPPORTED (TYPE:EMT)
BSMT FEEDER TO PANELS EMT NOT PROPERLY SUPPORTED 358.30
RSLV 09/01/2009 09/01/2009 10/08/2009
 
003 ( 56) ELECTRICAL MATERIAL USED IS NOT SUITABLE FOR THE PURPOSE INTENDED
PLP PANEL NEUTRAL TERMINALS NOT INSTALLED AFTER S/S 110.2
RSLV 09/01/2009 09/01/2009 10/08/2009
 
004 ( 59) AFCI PROTECTION HAS NOT BEEN PROVIDED
2,3,FL BEDROOM A/C NOT AFIC PROTECTED 210.12B
RSLV 09/01/2009 09/01/2009 10/08/2009
 
005 (999) OTHER
BOXES NOT FLUSH WITH FINISH SURFACE COLLARS NEEDED 314.20
RSLV 09/01/2009 09/01/2009 10/08/2009
 
006 ( 22) FIXED EQUIPMENT IS NOT PROPERLY GROUNDED
RECPT OUTLETS NOT GROUNDED 250.146
RSLV 09/01/2009 09/01/2009 10/08/2009
 
007 (999) OTHER
BOILER ROOM HI AND LO IN SAME RACEWAY 725.51/55
RSLV 09/01/2009 09/01/2009 10/08/2009
 
008 ( 62) ELECTRICAL PERMIT IS NOT CONSPICUOUSLY POSTED AT THE SITE
PERMIT TO PERFORM ELECT WORK NOT DISPLAYED 27.3018B
RSLV 09/01/2009 09/01/2009 10/08/2009