BIS Menu  |  Applications  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: B404514
NO JOBS FOUND WITH YOUR CRITERIA
Premises: 719 HENRY STREET BROOKLYN BIN: 3008454     Block: 536   Lot: 3
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 719 HENRY ST Census Tract:   59 Health Area:  4100
1ST-4TH FLS Admin Area:   B - BROOKLYN Inspection Area:   C
BROOKLYN, NY 11231 Community Board:   306
Related Job Number:    321240493
DOB Cross Street(s):   HUNTINGTON STREET,    WEST 9 STREET
Status:   C - JOB IS SIGNED OFF 11/22/2016
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  12/08/2015 12:21 PM
Application Entered:   12/08/2015 Job Start Date:   12/09/2015
Last Change:   11/22/2016 Job End Date:   06/30/2016
Appointment Status:   
Last Inspection By:   ROBINSON HEATH       On     04/22/2016      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 012216 Licensee Name: LARRY M ZASSMAN
Firm: 004467 Firm Name: VILLAGE ELECTL CONTRS INC
Firm Phone: 917-305-9050  Firm Address: 128-10 111TH STREET SOUTH OZONE PARK NY 11420 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $236.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   E - Four Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: ROBERT KAYDANIA
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  4  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  4  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  4  80AMP
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
001  1R    25    15             
002  2R    25    15             
003  3R    25    15             
004  4R    25    15             
Buildings Total   100    28  60                
Total Units : 188 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 03/16/2016
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  REPLACE 80AMP PANELS, FIXTURES, OUTLETS, SW

 
Inspection Details
 

*NO JOBS FOUND WITH YOUR CRITERIA
INSPECTION FOR APPLICATION #: B404514
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 03/15/2016 03/16/2016 CJH V (53) (2)
INSPECTION COMMENTS: FAIL
 
(2) 04/22/2016 04/26/2016 HRB C R (20) (0)
INSPECTION COMMENTS: PASSED

OBJECTION FOR APPLICATION #: B404514
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 16) DEFECTIVE LIGHTING FIXTURES ARE IN USE
(FLOOR: 001) ALL FLOORS HALLWAY LUMINAIRES 110.2A
RSLV 03/15/2016 03/15/2016 04/22/2016
 
002 (328) CIRCUIT CONDUCTORS NOT GROUPED
(FLOOR: 001) ALL FLOORS PNL CKT NOT GROUPED 210.4D
RSLV 03/15/2016 03/15/2016 04/22/2016



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Applications  |  Electrical Inspection Work Order  |  Back