Electrical Application Details for App #: M175581
NO JOBS FOUND WITH YOUR CRITERIA
Premises: 648 BROADWAY MANHATTAN BIN: 1008419     Block: 529   Lot: 3
   
Application Completed and Certified

Filed: 648 BROADWAY Census Tract:   55.02 Health Area:  5700
007348 3RD FLOOR Admin Area:   M - MANHATTAN Inspection Area:   S
NEW YORK, NY 10012 Community Board:   102
DOB Cross Street(s):   BLEECKER STREET,    BOND STREET
Status:   C - JOB IS SIGNED OFF 05/18/2000
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   02/25/1999 Job Start Date:   02/22/1999
Last Change:   05/18/2000 Job End Date:   03/20/1999
Appointment Status:   
Last Inspection By:   SEVERIANO JOHN       On     05/17/2000      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  G - NO COMMENT
Objection Disposition:  R - REMOVED

License #: 010142 Licensee Name: ETTORE BABICH
Firm: 000157 Firm Name: ARGON ELECTRICAL CORP
Firm Phone: 718-729-1380  Firm Address: 44-15 BARNETT AVENUE SUNNY SIDE NY 11104 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $199.25
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   Z - Other
Store / Other:   X
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: FRANMAR INFANTS WEAR INC
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  7  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  7  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 30  28  30                
Total Units : 95 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 7 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag: R - OBJECTION(S) RESOL
Power Requested: 05/10/1999 Notice:  12/17/1999
Power Issued: 05/10/1999 Response: R - REINSPECTION 2000110

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

*NO JOBS FOUND WITH YOUR CRITERIA
INSPECTION FOR APPLICATION #: M175581
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 11/10/1999 11/15/1999 SVJ N (5) (0)
INSPECTION COMMENTS: N/A LEFT CARD
 
(2) 12/16/1999 12/17/1999 SVJ V G (50) (2) Y
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 05/17/2000 05/18/2000 SVJ C R (20) (0) Y
INSPECTION COMMENTS: No Inspection Comments For This Application




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.