BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Y165646
NO JOBS FOUND WITH YOUR CRITERIA
Premises: 1041 EAST 179 STREET BRONX BIN: 2119487     Block: 3140   Lot: 2
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 1041 E 179 ST Census Tract:   361 Health Area:  2110
CELLAR-ROOF Admin Area:   Y - BRONX Inspection Area:   D
BRONX, NY 10460 Community Board:   206
Related Job Number:    220203401
DOB Cross Street(s):   BOSTON ROAD,    BRONX STREET
Status:   C - JOB IS SIGNED OFF 12/15/2015
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  09/04/2013 10:00 AM
Application Entered:   09/04/2013 Job Start Date:   09/04/2013
Last Change:   12/15/2015 Job End Date:   09/30/2014
Appointment Status:   
Last Inspection By:   DIMAGGIO, PHILLIP       On     12/14/2015      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 011877 Licensee Name: ANTHONY CERRITO
Firm: 003392 Firm Name: A & R ELEC'L MAINT. INC.
Firm Phone: 718-639-0800  Firm Address: 85-47 GRAND AVE ELMHURST NY 11373 

Work Started or Filed by Others: NO
Work Category:   N - NEW BUILDING Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
8 - BOILER/BURNER WIRING
Total Fee:  $3,298.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   YES
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: MIKE MCGUIRE
Owner Business Name: G. FAZIO
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  1  2000A 3PH
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  9  4# 1/0
C. Over 1/0 to 250 MCM  1  4 #250 MCM
D. Over 250 MCM  5  4 #600 MCM
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  65  12/24 CIRC
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  10  200A 3PH
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
CEL    48  40    16  48  30         
001    77  113  12  77         
002    59  165  31  59  65         
003    59  165  31  59             
004    59  165  31  59             
005    59  165  31  59             
006    59  165  31  59             
007    59  165  31  59             
008    59  165  31  59             
ROF    17    17  23  46         
Buildings Total 555  1312  65  248  555     147           
Total Units : 2882 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 1 #10-Wire 1
Existing Meters 0 + New Meters 2 - Removed Meters 0 = Total Meters 2

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 09/04/2013 Notice:  
Power Issued: 09/04/2013 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

*NO JOBS FOUND WITH YOUR CRITERIA
INSPECTION FOR APPLICATION #: Y165646
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 12/14/2015 12/15/2015 PDI C (2) (0) Y
INSPECTION COMMENTS: INSPECTION DONE ON 12/11/15 AT 1:45 TO 2:15 PM COULD NOT SYNC UP WITH INSPECTION READY COMPLETED AT BRONX OFFICE ON MONDAY AM. JOB ALL GOOD AND CERTIFIED.




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order