BIS Menu  |  Applications  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Y022644
NO JOBS FOUND WITH YOUR CRITERIA
Premises: 1822 DAVIDSON AVENUE BRONX BIN: 2008372     Block: 2861   Lot: 135
   
Application Completed and Certified

Filed: 1822 DAVIDSON AV Census Tract:   217.01 Health Area:  2210
ENTIRE BLDG Admin Area:   Y - BRONX Inspection Area:   E
BRONX, NY 10453 Community Board:   205
DOB Cross Street(s):   WEST 176 STREET,    WEST 177 STREET
Status:   C - JOB IS SIGNED OFF 04/30/1991
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   07/22/1988 Job Start Date:   07/20/1988
Last Change:   04/30/1991 Job End Date:   09/15/1990
Appointment Status:   
Last Inspection By:   TERRETT, R.       On     04/24/1991      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 010572 Licensee Name: CHRISTOS FAKATSELIS
Firm: 001636 Firm Name: POSITIVE ELECT'L ASSOC.IN
Firm Phone: 718-482-0202  Firm Address: 40-33 23RD STREET LONG ISLAND CITY NY 11101 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $1,852.75
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   C - Three Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: HPD
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  2  
D. 601 Up to 1200 AMPS  2  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  2  
D. Over 250 MCM  4  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  37  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  35  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  2  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 135  350  114  155  155                
Total Units : 909 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 35 #4-Wire 2 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: K - CANCELLED Objection Flag: R - OBJECTION(S) RESOL
Power Requested: 01/10/1991 Notice: 1 - FIRST NOTICE 11/30/1990
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  CTCE0158C22506

 
Inspection Details
 

*NO JOBS FOUND WITH YOUR CRITERIA
INSPECTION FOR APPLICATION #: Y022644
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 11/15/1990 11/16/1990 WMK A B (35) (5)
INSPECTION COMMENTS: /
 
(2) 11/29/1990 11/30/1990 WMK A R B (5) (7)
INSPECTION COMMENTS: / *A/ (27-3172A) OUTLETS NOT SUPPLIED BY TWO CIRCUITS *B/ (27 3045C4) SER SW ENCL NOT 125% OF LOAD *C/BONDING WIRE UNDER SIZE (273110A2)
 
(3) 01/03/1991 01/10/1991 WMK J Y B (75) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 04/24/1991 04/30/1991 RT1 C R E (60) (0)
INSPECTION COMMENTS: NONE




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Applications  |  Electrical Inspection Work Order  |  Back