DOB NOW: Inspections


Filed: 252 E 26 ST Census Tract:   792 Health Area:  5400
BASEMENT, 1ST & 2ND FLOORS Admin Area:   B - BROOKLYN Inspection Area:   G
BROOKLYN, NY 11226 Community Board:   317
DOB Cross Street(s):   CORTELYOU ROAD,    CLARENDON ROAD
Status:   E - ABANDONED 08/22/2025
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  08/24/2016 1:54 PM
Application Entered:   08/24/2016 Job Start Date:   08/25/2016
Last Change:   08/22/2025 Job End Date:   02/25/2017
               COMPLETION FEE WAS BILLED
Appointment Status:   
Last Inspection By:   MOSES, DANIEM       On     03/07/2017      
Field Disp:   N - NO ACCESS
Energize Recommendation:  
Objection Disposition:  

License #: 011495 Licensee Name: CLAIRMONT LONDON
Firm: 002966 Firm Name: CLAIRMONT ELEC'L CONTR'G
Firm Phone: 718-676-1537  Firm Address: 4113 AVENUE J,GROUND FLOOR INC. BROOKLYN NY 11210 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
5 - FIRE DAMAGE
6 - GENERAL WIRING
Total Fee:  $173.75
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   B - Two Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: PAULIN ETIENNE
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  2  60 AMPS DP
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  3  3 X #2 AWG & 3X # 6 AWG
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  3  12-24 BREAKER PANEL
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
001    27             
002    10  32  10             
Buildings Total 19  59  15  19                
Total Units : 121 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 3 #4-Wire 0 #10-Wire 0
Existing Meters 2 + New Meters 3 - Removed Meters 2 = Total Meters 3

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 08/24/2016 Notice:  
Power Issued: 08/24/2016 Response:  

Follow-Up:
Contractor's Comments:  FIRE DAMAGE, WIRING 1ST & 2ND FLOORS AND INSTALL 3 SERVICE METERS.

 
Inspection Details
 

*NO JOBS FOUND WITH YOUR CRITERIA
INSPECTION FOR APPLICATION #: B416262
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 03/07/2017 03/09/2017 DNM N (15) (0) Y
INSPECTION COMMENTS: ELECTRICIAN DID NOT SHOW.




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.