BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M051380
NO JOBS FOUND WITH YOUR CRITERIA
Premises: 42 CANAL STREET MANHATTAN BIN: 1003802     Block: 294   Lot: 25
  Printable (PDF) version of this Permit  

DOB NOW: Inspections


Filed: 42 CANAL ST Census Tract:   16 Health Area:  7400
BAS 3 4 5 FL Admin Area:   M - MANHATTAN Inspection Area:   V
NEW YORK, NY 10002 Community Board:   103
DOB Cross Street(s):   LUDLOW STREET,    ORCHARD STREET
Status:   E - ABANDONED 08/22/2025
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   04/25/1989 Job Start Date:   04/03/1989
Last Change:   08/22/2025 Job End Date:   05/15/1989
Appointment Status:   
Last Inspection By:   SEVERIANO JOHN       On     06/09/2008      
Field Disp:   J - JOB IN PROGRESS
Energize Recommendation:  G - NO COMMENT
Objection Disposition:  R - REMOVED

License #: 009295 Licensee Name: LAZAR MOSES
Firm: 001112 Firm Name: ORR ELECTRIC CORP
Firm Phone: 718-436-7581  Firm Address: 1338 44TH STREET BROOKLYN NY 11219 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $160.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   C - Three Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: JARWIN CANAL ASSOC
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  1  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  
D. Over 250 MCM  0  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  5  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  5  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 5 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: R - REQUESTED Objection Flag:
Power Requested: 09/12/1989 Notice: 1 - FIRST NOTICE 10/13/1995
Power Issued: Response:  

Follow-Up:
Contractor's Comments:  

 
Inspection Details
 

*NO JOBS FOUND WITH YOUR CRITERIA
INSPECTION FOR APPLICATION #: M051380
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 05/22/1989 06/13/1989 DH2 N (20) (0)
INSPECTION COMMENTS: LEFT CARD
 
(2) 11/28/1989 12/13/1989 DR1 P (45) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 03/23/1990 04/24/1990 DR1 P (70) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 12/04/1992 12/21/1992 PB1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(5) 01/15/1993 01/21/1993 PB1 V G (35) (2)
INSPECTION COMMENTS: N/C
 
(6) 05/21/1993 05/25/1993 DH1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(7) 06/04/1993 06/24/1993 FW1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(8) 07/14/1993 07/29/1993 FW1 N (15) (0)
INSPECTION COMMENTS: L C
 
(9) 05/26/1994 06/02/1994 KIW N (50) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(10) 09/22/1994 09/26/1994 KIW N (15) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(11) 03/22/1995 03/28/1995 KIW N (25) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(12) 09/29/1995 10/13/1995 KIW V R G (50) (3)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(13) 06/09/2008 06/14/2008 SVJ J R G (1) (0)
INSPECTION COMMENTS: VIOL REDIRECTED TO OWNER




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.