Electrical Application Details for App #: Z086170
NO JOBS FOUND WITH YOUR CRITERIA
Premises: 512 WEST 143 STREET MANHATTAN BIN: 1061865     Block: 2074   Lot: 47
   
Application Completed and Certified

Filed: 512 W 143 ST Census Tract:   229 Health Area:  0620
066885 NONE Admin Area:   Z - UPPER MANHATTAN Inspection Area:   B
NEW YORK, NY 10031 Community Board:   109
DOB Cross Street(s):   HAMILTON PLACE,    BROADWAY
Status:   C - JOB IS SIGNED OFF 08/13/2001
Request Type:   P - PICK-UP eFiled:   NO
Application Entered:   02/26/2001 Job Start Date:   03/28/2001
Last Change:   06/12/2001 Job End Date:   04/04/2001
Appointment Status:   
Last Inspection By:   DORSAINVILLE, R       On     06/04/2001      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 010903 Licensee Name: JOSE R MARTINEZ
Firm: 002184 Firm Name: C.E. ELECTRICAL CORP
Firm Phone: 888-779-7675  Firm Address: 32-10 57TH STREET STE 2 WOODSIDE NY 11377 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
9 - OTHER
Total Fee:  $102.50
Other Work:   VIOLATION REMOVAL
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   Z - Other
Store / Other:   DAY CARE CENTER
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: KAHARRY LAZARRE WHITE
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  1  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 36  41  26  36                
Total Units : 147 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag: R - OBJECTION(S) RESOL
Power Requested: Notice:  04/04/2001
Power Issued: Response: F - FILED TO REMOVE OBJECTION 04/20/2001

Follow-Up: X - FILED APPL,NOW CLOSED 04/20/2001
Contractor's Comments:  

 
Inspection Details
 

*NO JOBS FOUND WITH YOUR CRITERIA
INSPECTION FOR APPLICATION #: Z086170
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 02/21/2001 02/26/2001 RID W (5) (1)
INSPECTION COMMENTS: *BRANCH CIRCUIT WIRING,FIXTURES,RECERPTACLE OUTLETS,ETC SEE APP#Z083 489 THIS NOT A FINAL INSPECTION
 
(2) 06/04/2001 06/12/2001 RID C R (60) (0) Y
INSPECTION COMMENTS: No Inspection Comments For This Application