Electrical Application Details for App #: M042032
NO JOBS FOUND WITH YOUR CRITERIA
Premises: 112 MULBERRY STREET MANHATTAN BIN: 1002632     Block: 205   Lot: 7
   
Application Completed and Certified

Filed: 112-118 MULBERRY ST Census Tract:   41 Health Area:  6800
PARKING LOT Admin Area:   M - MANHATTAN Inspection Area:   U
NEW YORK, NY 10013 Community Board:   102
DOB Cross Street(s):   CANAL STREET,    HESTER STREET
Status:   C - JOB IS SIGNED OFF 04/21/1989
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   09/08/1988 Job Start Date:   09/14/1988
Last Change:   11/02/1988 Job End Date:   09/25/1988
Appointment Status:   
Last Inspection By:   COLON, WILFREDO JR       On     10/24/1988      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 005500 Licensee Name: E GURLEY
Firm: 000377 Firm Name: D.L. GURLEY & SONS
Firm Phone: 212-654-8803  Firm Address: 1256 EAST GUNHILL ROAD BRONX NY 10469 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
2 - TEMPORARY CONSTRUCTION
Total Fee:  $70.75
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   Z - Other
Store / Other:   CARNIVAL WIRING
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: MULBERRY ST FEAST
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  2  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  2  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total          125           
Total Units : 129 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Wires Comments: CARNIVAL TEMPORARY WIRING
Contractor's Comments:  

 
Inspection Details
 

*NO JOBS FOUND WITH YOUR CRITERIA
INSPECTION FOR APPLICATION #: M042032
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 09/15/1988 09/22/1988 WC1 J (60) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 10/24/1988 11/02/1988 WC1 C (25) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application