BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Z085160
NO PLUMBING INSPECTIONS COMPLETED FOR THIS PROPERTY
Premises: 2 WEST 125 STREET MANHATTAN BIN: 1053466     Block: 1722   Lot: 39
   
Application Completed and Certified

Filed: 2 W 125 ST Census Tract:   200 Health Area:  1500
168059 CHRISTMAS LGTS Admin Area:   Z - UPPER MANHATTAN Inspection Area:   C
NEW YORK, NY 10027 Community Board:   110
DOB Cross Street(s):    5 AVENUE,    LENOX AVENUE
Status:   C - JOB IS SIGNED OFF 02/20/2001
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   11/21/2000 Job Start Date:   11/24/2000
Last Change:   02/20/2001 Job End Date:   01/08/2001
Appointment Status:   
Last Inspection By:   ROGALEWSKI, M       On     02/07/2001      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 010610 Licensee Name: RICHARD NANNETTI
Firm: 002233 Firm Name: JOHN CAPPELLI ELEC'L INST
Firm Phone: 718-378-0100  Firm Address: 400 BARETTO STREET 1NC. BRONX NY 10474 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
9 - OTHER
Total Fee:  $27.00
Other Work:   TEMPORARY CHRISTMAS LIGHTING FROM POLE
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   Z - Other
Store / Other:   CHRISTMAS LIGHTING
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: 125 ST BID
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  1  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  1  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 1 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 11/21/2000 Notice:  
Power Issued: 11/21/2000 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  LAMPPOST IFO 2 WEST 125 STREET FEEDING 5 POLES

 
Inspection Details
 

*NO PLUMBING INSPECTIONS COMPLETED FOR THIS PROPERTY
INSPECTION FOR APPLICATION #: Z085160
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 02/07/2001 02/20/2001 MIR C (5) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application