BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M025427
NO PLUMBING INSPECTIONS COMPLETED FOR THIS PROPERTY
Premises: 61 BANK STREET MANHATTAN BIN: 1076888     Block: 624   Lot: 58
   
Application Completed and Certified

Filed: 61 BANK ST Census Tract:   77 Health Area:  6100
BSMT 2 3RD FL Admin Area:   M - MANHATTAN Inspection Area:   R
NEW YORK, NY 10014 Community Board:   102
DOB Cross Street(s):   WEST 4 STREET,    BLEECKER STREET
Status:   C - JOB IS SIGNED OFF 07/27/1988
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   08/31/1987 Job Start Date:   08/20/1987
Last Change:   07/27/1988 Job End Date:   11/20/1987
Appointment Status:   
Last Inspection By:   LEVEY, S.       On     07/21/1988      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  G - NO COMMENT
Objection Disposition:  

License #: 010247 Licensee Name: KENNETH TEICH
Firm: 001575 Firm Name: ELWOOD NY ELECTRIC CO INC
Firm Phone: 718-899-9798  Firm Address: 52-09 69TH STREET MASPETH NY 11363 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $268.75
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   A - One Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: JASHAW FEIGONBAUM
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  1  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  
D. Over 250 MCM  0  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  2  
B. Over #2 to 1/0  1  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  3  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 89  43    20  89                
Total Units : 241 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 1 #4-Wire 1 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 08/31/1987 Notice:  
Power Issued: 08/31/1987 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

*NO PLUMBING INSPECTIONS COMPLETED FOR THIS PROPERTY
INSPECTION FOR APPLICATION #: M025427
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 09/25/1987 10/02/1987 JNU J G (45) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 11/04/1987 11/06/1987 JNU J (45) (0)
INSPECTION COMMENTS: SERVICE NOT YET CONN TO CON ED DUT IN PROGERS
 
(3) 12/08/1987 12/10/1987 JNU J G (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 12/25/1987 01/11/1988 SM1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(5) 03/04/1988 03/22/1988 SM1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(6) 04/15/1988 05/11/1988 JNU Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(7) 05/27/1988 06/13/1988 SM1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(8) 07/21/1988 07/27/1988 SM1 C (60) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order