BIS Menu  |  Pre-BIS PA CO Query By Bin  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: B371482
NO PLUMBING INSPECTIONS COMPLETED FOR THIS PROPERTY
Premises: 1790 NOSTRAND AVENUE BROOKLYN BIN: 3120037     Block: 5195   Lot: 25
   
Application Completed and Certified

Filed: 1790 NOSTRAND AV Census Tract:   828 Health Area:  7410
BASEMENT, 1,2,3,4,5 APARTMENTS Admin Area:   B - BROOKLYN Inspection Area:   K
BROOKLYN, NY 11226 Community Board:   317
DOB Cross Street(s):   CLARENDON ROAD,    AVENUE D
Status:   C - JOB IS SIGNED OFF 07/22/2014 Balance Paid By Owner
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  08/19/2013 7:36 PM
Application Entered:   08/19/2013 Job Start Date:   08/20/2013
Last Change:   07/22/2014 Job End Date:   09/06/2013
Appointment Status:   
Last Inspection By:   THOMAS, PATRICIA       On     06/23/2014      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 011103 Licensee Name: VERE PADMORE
Firm: 002467 Firm Name: VERE ELECTRIC CORP.
Firm Phone: 718-783-2930  Firm Address: 726 STERLING PLACE BROOKLYN NY 11216 

Work Started or Filed by Others: YES
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $298.75
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: FOUST JOHN
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  1  200 A SERVICE SW
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  5  #6X 3WIRES BX
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  2\0 THHN
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  5  8-16 CB PANEL
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
BAS    12                 
001  12               
002  12               
002  12               
003  12               
003  12               
Buildings Total 37  62  10  36                  
Total Units : 145 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 7 #4-Wire 0 #10-Wire 0
Existing Meters 7 + New Meters 7 - Removed Meters 7 = Total Meters 7

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 08/19/2013 Notice: 1 - FIRST NOTICE 06/27/2014
Power Issued: 08/19/2013 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  BRANCH WIRING TO 3 FLOORS AND BASEMENT. WORK DONE BY OTHERS

 
Inspection Details
 

*NO PLUMBING INSPECTIONS COMPLETED FOR THIS PROPERTY
INSPECTION FOR APPLICATION #: B371482
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 09/04/2013 09/10/2013 CJE N (60) (0) Y
INSPECTION COMMENTS: NO ACCESS. CONTRACTOR NO SHOW
 
(2) 05/29/2014 06/02/2014 JTE N (30) (0) Y
INSPECTION COMMENTS: CONTRACTOR NO SHOW
 
(3) 06/13/2014 06/27/2014 JTE V E (50) (5) Y
INSPECTION COMMENTS: MUST RE INSPECT ALL AFCI CKTS IN ALL APTS
 
(4) 06/23/2014 06/30/2014 PAT C R E (45) (0) Y
INSPECTION COMMENTS: N

OBJECTION FOR APPLICATION #: B371482
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
NO COMMUNICATION BAR PROVIDED 250.96
RSLV 06/13/2014 06/13/2014 06/23/2014
 
002 (999) OTHER
CELLAR PLP PANEL CKTS NOT GROUPED 210.4D
RSLV 06/13/2014 06/13/2014 06/23/2014
 
003 ( 19) DEFECTIVE WIRING IS IN USE
ALL FLOORS 12.4 CKTS FOR SINGLE PHASE PANELS
RSLV 06/13/2014 06/13/2014 06/23/2014
 
004 (999) OTHER
ALL FLOORS MULTIWIRE CKTS FOR AFCI NOT ON COMMON TRIP 210.4B
RSLV 06/13/2014 06/13/2014 06/23/2014
 
005 (315) CONDUCTORS NOT PROPERLY IDENTIFIED
ALL FLOORS 12.4 CKTS BLUE WIRE REIDENTIFIED AS WHITE CONDUCTORS
RSLV 06/13/2014 06/13/2014 06/23/2014



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.